Malfunction
Air in the water circuit
Noises caused by vibrations.
Bearing damage in the device-internal circula-
tion pump.
Device-internal circula-
tion pump is excessively
noisy while running
Water pressure at pump inlet too low.
Expansion tank is defective.
Water pressure in the heating system is too
high.
Safety pressure relief
valve is leaking or always
open.
Safety pressure relief valve is stuck.
Tab. 8-1 Possible malfunctions of the Daikin Altherma EHS(X/H)

8.3 Fault codes

In the case of all malfunctions / error messages due to possibly defective sensors, all associated connection cables, con-
nection points (plug contacts correctly in place) and printed circuit boards must be checked before replacing the sensor.
Component allocation: see fig. 3-1 to fig. 3-5 and fig. 8-4
Code
Malfunction /
Error messages
Display Internal
E9001
80
Fault T-return
E9002
81
Fault feed flow
Frost protection
E9003
89
function error
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN
8
Possible cause
Component/Designation
Sensor or connection cable defective.
Return flow temperature
sensor t
R2
Sensor or connection cable defective.
Flow temperature
sensor t
or t
V1
V, BH
Measured value t
– Failure of the frost protection function for the plate heat
Plate heat exchanger
(PHE)
– Failure of the frost protection function of the plate heat
x
Errors, malfunctions and messages
Possible solution
Fully vent the heating system and device-internal
circulation pump.
Check the Daikin Altherma EHS(X/H), its components
and covers to ensure they are fastened correctly.
Reduce pump speed [Min Perform Pump] and [Max
Perform Pump]).
Replace device-internal circulation pump.
On the controller (rotary switch setting "Info"
check whether there is adequate water pressure
(>0.5 bar).
Check that the pressure gauge is working correctly
(connect an external pressure gauge).
Check the primary pressure in the expansion
container and the water pressure, if necessary, refill
the heating water and reset the primary pressure
(see chapter 7.4).
Replace expansion tank.
On the control unit (rotary switch position "Info"
check that the water pressure lies beneath the stated
maximum pressure. If necessary, bleed the water until
the pressure lies in central permissible range.
Check safety pressure relief valve and if necessary,
replace it.
– Turn the red knob on the safety pressure relief
valve counterclockwise. If you can hear a rattling
noise, the safety pressure relief valve needs
replacing.
Causes and possible error correction
Check, replace.
Check, replace.
<0 °C
V1
exchanger because the water flow is too low. See error code
E9004 / 7H.
exchanger because there is a lack of coolant in the system.
See error code E9015 / E4.
)
)