3

Product description

3.1 Design and components

3.1.1 Top of unit

Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN
3
x
1
Solar - flow (1" IG)
2
Cold water flow (1" AG)
3
Hot water flow (1" AG)
4
Heating flow (1" AG)*
5
Heating return (1" AG)*
6
Circulation pump
7
Safety-pressure relief valve (heating circuit)
8
Automatic vent
17
Fill level indicator (tank water)
18
Connection for electrical Backup-Heater EKBUxx (R 1½" IG)
(Accessory)
30
Plate heat exchanger (PWT)
31
Connection coolant fluid line
Daikin Altherma EHS(X/H)(B)04P30B/08PxxB: Cu Ø 6,4 mm
(1/4"),
Daikin Altherma EHS(X/H)(B)16P50B: Cu Ø 9.5 mm (3/8")
32
Connection to coolant gas line
Cu Ø 15,9 mm (5/8")
34
Ball cock (heating circuit)*
35
Combined filling and draining valve (heating circuit)
37
Storage tank temperature sensor t
38
Connection diaphragm expansion vessel
39
Controller housing with elect. terminal strip
3UVB1
3-way diverter valve (internal heat generator circuit)
3UV DHW
3-way diverter valve (hot water / heating)
DS
Pressure sensor
FLS (t
/ V1)
R1
Return flow temperature and flow sensor
t
Return flow temperature sensor
R2
t
Inflow temperature sensor
V1
t
V, BH
Flow temperature sensor Backup-Heater
Safety devices
Observe tightening torque!
AG Male thread
IG
Female thread
*
Ball cock (1" IG) is supplied with the equipment
Fig. 3-1
Structure and components Daikin Altherma EHS(X/H)
(top of unit)
Product description
and t
DHW1
DHW2
Installation and operating instructions
9