EKKO
User Manual
Manual unlocking operation: turn the cover 180°, insert the key and turn 90° anticlockwise, the gate leaf can be pushed manually, close the cover. To re-lock
the gate leaf, insert and turn the key clockwise.
- In the event of mains power failure, the back-up battery ensures the operation of the automation system for a limited period. Should the battery be flat
or missing, manually unlock the motor, open the door, insert the unlocking key and turn anticlockwise; it is advisable to move the gate into the fully open
position and reset unlocking by turning the key clockwise and close the cover, which is to prevent any unwanted movement of the gate (with the operator
unlocked the gate leaf is free to move, which could cause damage to property or persons). Once the power supply is restored, the electronic board will
charge the back-up battery and the gate will return to normal operation after a command pulse.
CAUTION: Unlock and reset with the gate stationary.
180°
Maintenance: Periodically check the fixing screws, the integrity of the connecting cables, the correct functioning of the safety systems (photocells and sen-
sitive edges), the robustness of the mechanical stops and the soundness of the systems for supporting the gate leaf (hinges or bearings). Every 2 years it is
recommended to replace the batteries in the remote control.
Location of the buttons for controlling the gate (selectors, keypads, buttons, etc.)
Control device
If the automatic closing function is active (when the gate is stationary and open the flashing light stays on for 3 seconds) the gate closes after the set time.
You can disable this function by pressing the button on the remote control before the gate reaches the fully open position. If the sequential function is active
it opens-stops-closes.
If the gate meets an obstacle on closing, and automatic closing is active, the control unit makes 2 attempts at closing, after which it remains open.
It is necessary to remove the obstacle from its path and control the gate with the remote control so that it closes at low speed.
16
90°
Location
EN