TECHNICAL DATA
BATTERY-LAMP
Lightning time with one fully charged battery (5.0 Ah)
High Level ............................................................................
Med Level ............................................................................
Low Level ............................................................................
Luminous fl ux
High Level ............................................................................
Med Level ............................................................................
Low Level ............................................................................
Colour rendering index (CRI)..................................................
Colour temperature.................................................................
Battery voltage........................................................................
AC input ..................................................................................
Charger rated power input ......................................................
Charger output........................................................................
Quick charge current ..............................................................
Battery charging time with 5.0 Ah ...........................................
Battery charging time with 6.0 Ah ...........................................
Battery charging time with 9.0 Ah ...........................................
Weight without battery ............................................................
Weight according EPTA-Procedure 01/2003 (2.0 Ah) ............
Weight according EPTA-Procedure 01/2003 (5.0 Ah) ............
Weight according EPTA-Procedure 01/2003 (9.0 Ah) ............
Protection class ......................................................................
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
BATTERY LAMP SAFETY INSTRUCTIONS
Warning: Do not direct the light beam at persons or animals
and do not stare into the light beam yourself (not even from
a distance). Staring into the light beam may result in serious
injury or vision loss.
Caution – this product is provided with cooling openings in
the bottom enclosure. Only install this luminaire on a surface
that will not allow accumulation of water into the housing.
Keep the product away from puddles,etc.
CHARGER SAFETY INSTRUCTIONS
Do not store the battery pack together with metal objects
(short circuit risk).
Battery Cat.
DC Volts
Capacity
Cell No.
No.
M18B
18
≤ 1.5 Ah
M18BX
18
≤ 3.0 Ah
M18B2
18
≤ 2.0 Ah
M18B4
18
≤ 4.0 Ah
M18B5
18
≤ 5.0 Ah
M18B6
18
≤ 6.0 Ah
M18B9
18
≤ 9.0 Ah
Do not try to charge non-rechargeable batteries with this
charger.
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised Service Agents.
This appliance is not intended to
be used or cleaned by persons
18
ENGLISH
М18 HSAL
........................2,25 h
........................4,25 h
.............................8 h
.......................3000 lm
.......................1700 lm
.........................900 lm
...........................80
.......................4000 K
...........................18 V
..................100-240 V
......................... 110 W
...........................18 V
.............................3 A
...........................80 min
.........................100 min
.........................160 min
..........................9,2 kg
..........................9,5 kg
..........................9,9 kg
........................10,3 kg
....................... IP34
with reduced physical, sensory or
mental capabilities, or lack of
experience or knowledge, unless
they have been given instructions
concerning the safe use of the
appliance by a person legally
responsible for their safety. They
should be supervised whilst using
the appliance. Children shall not
use, clean or play with this
appliance, which when not in use
should be secured out of their
reach.
5
2 x 5
ADDITIONAL SAFETY INSTRUCTIONS
5
Remove the battery pack before starting any work on the
2 x 5
appliance.
2 x 5
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors offer to
2 x 5
retrieve old batteries to protect our environment.
3 x 5
Do not store the battery pack together with metal objects
(short circuit risk).
Use only compatible Milwaukee chargers from the same
battery platform for charging battery packs. Do not use
battery packs from other systems.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
SPECIFIED CONDITIONS OF USE
The area light is intendend to be used light independent use
away from mains supply.
Additionally the charger can charge the specifi ed Milwaukee
battery packs.
Do not use this product in any other way as stated for
normal use.
CHARGING
After inserting the battery into the reception of the charger
the battery will automatically be charged (red lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(0°C...60°C).
Charging time varies depending on the battery temperature,
charge needed and the type of battery pack being charged.
As soon as charging is completed, the charger switches
over to "trickle" charge to maintain the full capacity (green
control lamp is illuminated continuously, red lamp off)
If both LEDs fl ash at the same time, either the battery has
not been completely mounted or there is a fault in the
battery or the charger. For safety reasons you must stop
using the charger and battery immediately and have them
inspected by an Milwaukee Customer Service Centre.
BATTERIES
Battery packs which have not been used for some time
should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
For an optimum life-time, the battery packs have to be fully
charged, after used.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods
Legislation requirements.
Transportation of those batteries has to be done in
accordance with local, national and international provisions
and regulations.
• The user can transport the batteries by road without
further requirements.
• Commercial transport of Lithium-Ion batteries by third
parties is subject to Dangerous Goods regulations.
Transport preparation and transport are exclusively to be
carried out by appropriately trained persons and the
process has to be accompanied by corresponding experts.
When transporting batteries:
• Ensure that battery contact terminals are protected and
insulated to prevent short circuit.
• Ensure that battery pack is secured against movement
within packaging.
• Do not transport batteries that are cracked or leak.
Check with forwarding company for further advice
MAINTENANCE
The light source of this luminaire is not replaceable; when
the light source reaches its end of life the whole luminaire
shall be replaced.
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our Milwaukee service
agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the machine type printed as well as the six-digit
No. on the label and order the drawing at your local service
agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket
before carrying out any work on the machine.
CAUTION: Possibly hazardous optical radiation
emitted from this product. Do not stare at
operating lamp. May be harmful to the eye.
Please read the instructions carefully before
starting the machine.
Do not dispose of electric tools together with
household waste material.
Electric tools and electronic equipment that have
reached the end of their life must be collected
separately and returned to an environmentally
compatible recycling facility.
Check with your local authority or retailer for
recycling advice and collection point.
Class II tool.
Tool in which protection against electric shock
does not rely on basic insulation only, but in
which additional safety precautions, such as
double insulation or reinforced insulation, are
provided.
There being no provision for protective earthing
or reliance upon installation conditions.
Do not burn used battery packs.
Never charge a damaged battery pack. Replace
by a new one.
Time-lag fuse 3.15 A
T3.15A
European Conformity Mark
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
19