6
Insert the control cable from the control unit in the
socket on the appliance. Plug together the supply
cables of the control unit and of the remote fan unit.
The plugs must engage. Connect the control unit to
the mains and check that it is working. If the
appliance is not working, check that the connecting
cables are fitted correctly.
7
Flush installation only: it is imperative to test
functioning before jointing!
gap with a suitable, temperature-resistant silicone
adhesive (such as OTTOSEAL
the seal joint with smoothing agent recommended
by the manufacturer. Observe the notes on
processing the silicone adhesive. Do not operate
the appliance until the silicone adhesive has dried
completely (at least 24 hours, depending on room
temperature).
NOTICE: Unsuitable silicone adhesive used on
natural stone worktops will cause permanent
discoloration.
Connect Electrical Supply
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
Attach flexible conduit to the junction box. Connect the
lead wires to the junction box supply wires in proper
phase:
▯
black (L1) to black
▯
red (L2) to red
▯
green to ground
14
Joint the surrounding
S 70). Smoothen
®
The mains connecting cable must at least correspond to
the type SJTO 3x16 AWG 105°C. The mains connecting
cable must only be purchased through and connected
by an authorised specialist.
Connection with a plug
▯
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
▯
The appliance must be properly grounded.
▯
Plug must be rated not less than type 6-20 P (2-pole
3-wire grounding).
▯
Only a qualified electrician should connect the
plug.
▯
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still
be accessible after installation.
Ventilation molding
If downdraft ventilation is used next to a gas appliance,
a ventilation molding AA 414 010 must be fitted on the
gas appliance during cooking. The ventilation molding
improves extraction when using gas appliances. The
ventilation molding prevents extinction of small flames
due to the draft.
AA 414 010
Ventilation molding, for operation next
to the VG 414/415/424/425 gas
appliance
Removing appliance
Disconnect the appliance from the power supply. For
flush-mounted appliances, remove the silicone joint.
Push out the appliance from below.
9
CAUTION
Damage to appliance! Don't lever device out from
above at the frame.