P R O 4 8
I N S TA L L AT I O N
The PRO 48 can be used free-standing or
installed as a standard or flush built-in
application. For standard built-in installa-
tions, the face frame of the unit will extend
51 mm beyond cabinetry. In flush built-in
installations, the front of the face frame will
be flush with surrounding cabinetry.
For built-in installations, make sure that the
finished rough opening where the unit is to
be installed is properly prepared. Refer to
the Installation Specifications illustration to
be sure that the rough opening dimensions,
electrical service and plumbing are correct.
8
I N S TA L L A T I O N S P E C I F I C AT I O N S
S P E C I F I C A T I O N S
IMPORTANT NOTE: To operate properly,
doors must be able to open a minimum of 90˚.
Use a filler strip in built-in corner installations
to assure a 90˚ door opening. Allow enough
clearance in front of the unit for full door
swing.
IMPORTANT NOTE: Make sure that the floor
under the unit is level with the surrounding
finished floor and will be able to support the
weight of the unit—401 kg or 408 kg.