ELECTRICAL CONNECTIONS (CONT.)
4
3-WIRE POWER CORD INSTALLATION
WARNING: The neutral or ground wire of the
power cord must be connected to the neutral
terminal located in the center of the terminal
block. The power leads must be connected to
the left and the right terminals of the terminal
block.
A
Remove the 3 lower terminal screws from the terminal
block. Insert the 3 power cord terminal rings into each one
of the terminals of the terminal block. Be certain that the
center wire (white/neutral) is connected to the center of
the terminal block. Tighten nuts securely into the terminal
block.
DO NOT remove the ground strap connection.
Ground
plate
Power
cord
B
Skip to Step 8 and proceed with the installation.
82
Installation Instructions
Terminal block
(appearance
may vary)
Neutral
terminal
Ground
strap
5
4-WIRE POWER CORD INSTALLATION
WARNING: The neutral wire of the supply cir-
cuit must be connected to the neutral terminal
located in the center of the terminal block. The
power leads must be connected to the left and
the right terminals of the terminal block. The
4th grounding lead must be connected to the
frame of the range with the ground plate and
the ground screw.
A
Remove the 3 lower terminal nuts from the terminal block.
Remove the ground screw and ground plate and retain
them.
B
Cut and discard the ground strap. DO NOT DISCARD ANY
SCREWS.
C
Insert the one ground screw into the power cord ground
wire terminal ring, through the ground plate and into the
frame of the range.
D
Insert the 3 terminal screws (removed earlier) through
each power cord terminal ring and into the lower terminals
of the terminal block. Be certain that the center wire
(white/neutral) is connected to the center lower position of
the terminal block. Tighten screws securely into the termi-
nal block.
Before
Terminal
block
Ground strap
After
Terminal
block
Ground
screw
E
Skip to Step 8 and proceed with the installation.
Ground strap
or
Neutral
terminal
Neutral terminal
Ground
plate
(grounding
to range)