VI.
CONTROLLER PROGRAMMING INSTRUCTIONS (cont.)
Select Display Units
Hold the 56 buttons simultaneously for 3 seconds to
enter the program mode. Press the 6 button once.
The display should now read level 1. Hold the Ý button
and press the 5 button once to get to level 2. Press
the 5 button eleven times until the display reads unit
and blinks F. Hold the Ý button and press the 6 button
once. The display should now read C. Hold the 56
buttons simultaneously for 3 seconds to exit the pro-
gram mode. The controller will now indicate tempera-
ture in degrees Celsius.
Alarm
The controller comes from the factory with the alarm
function disabled. To utilize the alarm function set the
desired band and sensitivity.
Band
Hold the 56 buttons simultaneously for 3 seconds to
enter the program mode. Press the 6 button once.
Phoenix International, Inc. warrants its products against defects in material and
workmanship. The company will, at its discretion, repair or replace any prop-
erly installed Phoenix International manufactured product which fails under
normal operating conditions within one year from date of receipt. Contact the
factory for return authorization before returning the product to Phoenix
International freight prepaid. If our inspection confirms that the product is
defective under terms of this warranty, it will be repaired/ replaced and returned
freight prepaid.
Phoenix International, Inc.
8711 West Port Avenue
Milwaukee, WI 53224 USA
The display should now read level 1. Hold the Ý button
and press the 5 button once to get to level 2. Press
the 5 button 5 times until the display reads SP2.A and
blinks none. Hold the Ý button and press the 5 button
three times. The display should now read band. Hold
the 56 buttons simultaneously for 3 seconds to exit
the program mode. The alarm function is now active.
Sensitivity
Hold the 56 buttons simultaneously for 3 seconds to
enter the program mode. Press the 5 button eleven
times. The display should now read SET.2. Hold the Ý
button and press the 5 button to desired alarm band
width. Hold the 56 buttons simultaneously for 3 sec-
onds to exit the program mode. The alarm is now set.
Note: If the temperature goes outside of the Alarm tem-
perature band after reaching set point, the alarm will
activate. The alarm is indicated by a flashing red light
on the bottom right of the face and the display will blink
-A-.
This warranty applies only to Products sold by Phoenix International, Inc. and
specifically excludes installation or de-installation labor, transportation, or
equipment of another manufacturer used in conjunction with Phoenix
International products. No other warranty, expressed or implied, exists beyond
this warranty declaration.
Phoenix constantly strives to improve its products and therefore reserves the
right to change design, materials, and specifications without notice.
Phone (414) 973-3400
Fax (414) 973-3210
www.phx-international.com
info@phx-international.com
N5406800E-15