All wiring should be done by licensed electricians in accordance with local codes. Improper instal-
lation or use may result in serious injury. Always remove oven from power source before trou-
bleshooting or repairing.
II.
OVEN TYPE DESCRIPTION (cont.)
CAUTION
DO NOT OPERATE THE OVEN ABOVE 800° F
Description of Controls
A. The controller in this oven is a full-indicating,
PID (proportional, integral, derivative) controller
using a Type J thermocouple sensor. The con-
troller is factory set for optimum performance accu-
racy with a 400 lb load at maximum temperature.
To set the temperature controller at desired oven
temperature; Hold the
6
button to change the set-point.
B. The high-limit control is a mechanical device
with on-off control action and a manual reset. The
high-limit control will shut down the oven heat
when the oven temperature reaches the high-limit
set point. The red indicator light with the message
"RESET" on the control will illuminate if this occurs
and will stay lit until the reset button is pushed. In
**CAUTION**
Ý
button and press the
order to regain power to the heating elements, the
oven must cool down below the high-limit set tem-
perature and the reset button must be pushed
Guide to Storage
In the absence of detailed storage information from
your electrode manufacturer, the "Revised Guide To
Electrode
Storage"
International, Inc.) may be used as an indication of
approximate temperatures. For Specific information
5 or
involving critical operations be sure to contact your
electrode/flux manufacturer for complete informa-
tion.
Warning
Excess Heat: At the maximum setting, the actual
temperature in portions of the oven near the heating
elements may exceed the upper range.
(available
from
Phoenix
N5406800E-5