Installation, use and maintenance
I
OPERATING CONDITIONS
I1
ENVIRONMENTAL CONDITIONS
TEMPERATURE
RELATIVE
HUMIDITY
LIGHTING
ATTENTION
I2
POWER CONSUPTION
NOTA
ATTENTION
I3
WORKING CYCLE
NOTE
I4
PERMITTED AND NON-PERMITTED FLUIDS
PERMITTED
DIESEL WITH A VISCOSITY BETWEEN 2 AND 5.35 cST (AT A TEMPERATURE
OF 37.8 °C)
FLUDS
MINIMUM FLASH POINT (PM): 55 °C
Ref: EN5902010 dtd. 25/03/2010
NON
ALL THE FLUIDS NOT MENTIONED IN "ADMITTED FLUIDS"
PERMITTED
FLUIDS
44
/56
min. 20 °C / max +60 °C
max. 90%
The environment must conform to directive 89/654/EEC on work environ-
ments. In case of non-EU countries, refer to directive EN ISO 12100-2 §
4.8.6.
The temperature limits shown apply to the pump components and must be
respected to avoid possible damage or malfunction.
Depending on the model, the pump must be fed by single-phase alternating
current whose nominal values are those indicated in the Table.
The maximum acceptable variations from the electrical parameters are:
Voltage:+/- 5% of the nominal value
Frequency:+/- 2% of the nominal value
Power from lines with values outside the indicated limits can damage the
electrical components.
The motors are intended for continuous use. Under normal operating condi-
tions they can function continuously with no limitations
M0362 A ml