Electrical Connections - Piusi E300 Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation, use and maintenance
L5

ELECTRICAL CONNECTIONS

FOREWORD
ATTENTION
DIREC-
TION FOR
CORRECT
ELECTRICAL
INSTALLA-
TION
W2
C
U1
ATTENTION
48
/56
The electrical connections must be performed in a workmanlike manner by
skilled personnel, respecting the regulations in effect in the country of instal-
lation. To make the necessary connections, refer to the electrical wiring
diagram in this manual.
Respect the following (not exhaustive) instructions to ensure a proper elec-
trical installation:
• During installation and maintenance make sure that power to the electric
lines has been turned off.
Employ cables characterized by minimum cross-sections, rated voltages
and installation type adequate to the characteristics indicated in paragraph
ELECTRICAL SPECIFICATIONS and the installation environment.
•All motors are equipped with a ground terminal to connect to the ground
line of the electrical network
Always close the cover of the terminals trip box before turning on the
electric power, after checking the integrity of the gasket seals.
The unit is not equipped with circuit breakers. It is therefore recom-
mended to install a 30-mA residual current operated circuit breaker on
the plug. Protection: minimum 10 Amp.
C = Capacitor
U2
V2
V1
W1
Single-phase motors are supplied with a bipolar switch and capacitors
wired and installed inside the terminal strip box (see chart). The capaci-
tor characteristics are those indicated on the pump label. The switch
has the function of starting/stopping the pump and cannot in any way
replace the main power switch required by the applicable regulations.
W2
C
U1
W1
M0362 A ml

Publicidad

Tabla de contenido
loading

Tabla de contenido