Converting Type 1 Pressure Regulator for
Use with LP/Propane
This cooktop arrives from factory adjusted for use with
natural gas. If using LP/propane gas cooktop must be
converted.
1. Remove pressure regulator cap using 7/8" wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Insert must show "LPG10" or "LP10".
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of
regulator.
Converting Type 2 Pressure Regulator for
Use with LP/Propane
1. Remove pressure regulator cap using 7/8" wrench.
2. Reverse pressure regulator cap.
• Insert must show "LP".
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Burners for Use with LP/
Propane
1. Remove control knobs, grates, caps, and burner
bowls.
2. Remove burners by removing burner screw with
phillips screwdriver. Unplug burners from burner
wires.
3. Lift maintop off burner box to expose air shutters.
• Orifice hoods will be visible.
A
B
1/8" nominal
A. Orifice Hood
B. Air Shutter
C. Venturi Tube
4. Turn orifice hoods clockwise approximately 1 1/2 to
2 turns (close) until snug against pin.
• Do not overtighten hoods to avoid damaging
hoods.
5. Reassemble cooktop.
6. Adjust burner flame if necessary.
• See Adjusting Surface Burner Flame section.
Converting Type 1 Pressure Regulator for
Use with Natural Gas
1. Remove pressure regulator cap using a 7/8"
wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Insert must show "NAT" or be blank.
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of
regulator.
Converting Type 2 Pressure Regulator for
Use with Natural Gas
1. Remove pressure regulator cap using 7/8" wrench.
2. Reverse pressure regulator cap.
• Insert must show "NAT" or be blank.
3. Place pressure regulator cap on pressure regulator
and tighten.
5
C