Operation
Operating Burners
1. Push and turn burner control knob to "LITE"
position.
• Burner sparks until turned from "LITE".
2. Turn burner control knob to desired setting.
3. Turn burner control knob to "OFF" position when
finished.
Control Knobs
Back left burner knob
Back right burner knob
Front left burner knob
Front right burner knob
Adjusting Surface Burner Flame
Properly adjusted surface burner flames are clean and
blue with a distinct inner cone approximately 1/4 inch to
1/2 inch long. See "Operating Burners" section for
burner operating instructions.
• If burner flame is blowing or noisy, reduce airflow
to burner by adjusting air shutter.
• If burner flame is yellow and does not hold its
shape, increase airflow to burner by adjusting air
shutter.
A. 1/4" to 1/2" inner cone length.
Adjusting Air Shutter
1. Remove control knobs, grates, caps, and burner
bowls.
2. Remove burners by removing burner screw with
phillips screwdriver. Unplug burners from burner
wires.
3. Lift top up off burner box to expose air shutters.
4. Slide air shutter open or closed depending on
appearance of burner flame.
• If flame is yellow and does not hold its shape,
open air shutter.
• If flame is blowing or noisy, close air shutter.
A
B
1/8" nominal
A. Orifice Hood
B. Air Shutter
C. Venturi Tube
5. Reassemble.
6. After adjustment retest burner flame.
8
A
Burner
C