Gas Regulator Position
C
Gas Regulator
Position
A. 2" in from rear of cutout.
B. 2" in from right side of cutout.
C. 7 1/8" down from top of cutout. Connection point for
house gas hookup.
• Do not overtighten regulator when attaching to gas
manifold pipe. Overtightening may crack regulator.
• Do not overtighten fitting or hard pipe when
attaching to gas regulator.
• Support regulator when installing.
Testing for Gas Leaks
WARNING
To avoid property damage or serious personal
injury, never use a lighted match to test for
gas leaks.
After final gas connection is made, test all connections
in gas supply piping and cooktop for gas leaks.
1. Place soap suds on connection.
• Bubbles appear if leak is present.
2. Tighten joint if leak is at factory fitting.
• If leak is not at factory fitting, unscrew, apply more
joint compound, and tighten to correct leak.
3. Restart connection for leak after tightening.
• Retest any connections that were disturbed.
CAUTION
To avoid property damage, maximum gas
supply pressure must not exceed 14" WCP.
Gas Regulator
Position
A
B
Electrical Installation Requirements
Installation of this product must conform with local codes
or in absence of local codes, with current Canadian Gas
Installation Code CAN/CGA-B149.2. If an external
electrical source is used when appliance is installed, it
must be electrically grounded in accordance with local
codes or, in absence of local codes, with current National
Electrical Code ANSI NFPA 70, or CSA Standard C22.1,
Canadian Electrical Code, Part 1.
In Canada all electrical connections are to be made in
accordance with CSA Standards Z240.6.1 electrical
requirements for mobile homes.
Use a dedicated 120 volt, 60 hertz, 3-prong receptacle
protected by a 15 amp circuit breaker or time delay fuse.
A qualified electrician should confirm the outlet is
properly grounded. Cooktop includes 4-foot power cord
attached to bottom of cooktop at back, left corner.
If a 2-prong outlet is encountered, cooktop owner must
replace outlet before using cooktop. Do not cut off cord
or remove grounding prong.
Replacing Burner Caps
To replace burner caps after cleaning, make sure cap is
dry, properly aligned and leveled. Verify locating pegs in
the burner body fit into recess in underside of burner
cap. Burner cap must be correctly seated on burner
body for proper operation of burner. Burner will not burn
properly if wrong size burner cap is placed on wrong
size burner body. Check for ignition after placement.
Burner cap
7
Burner body