2.2.1. Personnel
WARNING
Only qualified and professional personnel, based on their training, experience and instruction as well
as their knowledge of the regulations, the safety rules and operations performed, are authorized to
carry out necessary work.
2.2.2. Transport
The following points must be observed to ensure proper operation of the system:
• do not lay down or flip over the softener at any time. The media may paste to the upper distributor thus obstructing its slots
or enter the valve and may therefore compromise the softener operation;
• pay attention not to hit the softener;
• use all the safety lifting systems to move the softener;
• do not lift the softener by the valve or bypass.
2.2.3. Material
The following points must be observed to ensure proper operation of the system and the safety of user:
• beware of high voltages present on the transformer (100-240VAC);
• do not put your fingers in the system (risk of injuries with moving parts and shock due to electric voltage).
2.3.

Hygiene and sanitization

2.3.1. Sanitary issues

Preliminary checks and storage
• Check that the brine tank and the brine well are clean and free from burr, debris or any scraps;
• check the integrity of the packaging. Check that there is no damage and no signs of contact with liquid to make sure that no
external contamination occurred;
• the packaging has a protective function and must be removed just before installation. For transportation and storage
appropriate measures should be adopted to prevent the contamination of materials or objects themselves.
Assembly
• Assemble only with components which are in accordance with DM 174 and ACS or any local norm/certification;
• after installation and before use, perform one or more manual regenerations in order to clean the media bed. During such
operations, do not use the water for human consumption. Perform a disinfection of the system in the case of installations
for treatment of drinking water for human use.
NOTE
This operation must be repeated in the case of ordinary and extraordinary maintenance. It should also
be repeated whenever the system remains idle for a significant time.
NOTE
Valid only for Italy: In case of equipment used in accordance with the DM25, apply all the signs and
obligations arising from the DM25.

2.3.2. Hygiene measures

DANGER
Do not use with water that is micro-biologically unsafe or of unknown quality without adequate
disinfection before or after the softener.
WARNING
Water softeners using sodium chloride for regeneration will add sodium to the water. Person who are