Installation Guide
Heating cables
1
Introduction
In this installation manual, the phrase "heating cable" refers
to heating cables in readymade lengths; heating cables
on drums; heating cables on mesh; and preshaped taped
heating cables.
2
Safety instructions
Heating cables must always be installed according to local
building regulations and wiring rules as well as the guide-
lines in this installation manual.
• De-energize all power circuits before installation and service.
• Residual current device (RCD) protection is required. RCD trip
rating is max. 30 mA.
• The screen from each heating cable must be earthed in
accordance with local electricity regulations
• Heating cables must be connected via a switch providing
all pole disconnection.
• The heating cable must be equipped with a correctly sized
fuse or circuit breaker according to local regulations.
3
Installation guidelines
• It is not recommended to install heating cables at tem-
peratures below -5°C.
• Heating cable bending diameter must be at least 6 times
the cable diameter. Do not bend connections.
4
Mechanical class
M1— For use in applications with low risk of mechanical
damage according to IEC 60800:2009, e.g. installed on even
surfaces and embedded in screeds with no sharp objects.
M2 — Can be used in applications with high risk of mecha-
5
Warranty
A 20-year full service warranty is valid for:
• heating cables incl. ECflex, ECsafe, ECsnow, ECasphalt,
ECaqua, ECbasic, ECmulti, ECsport (DSM3), ECfreeze;
• heating mats incl. ECsnow, ECasphalt, ECflex, ECsafe.
Not only does this warranty include costs of reparation or
replacement, but also installation and floor materials, such as
damage to brickwork and tiles.
A 10-year product warranty is valid for:
• Danfoss Reflect, ECcell insulation plates.
A 5-year product warranty is valid for:
• self-limiting cables incl. ECiceguard, ECpipeheat, ECpipeguard,
EChotwatt.
Should you, against all expectations, experience a problem with
your Danfoss product, you will find that Danfoss offers Danfoss
warranty from the date of purchase on the following conditions:
During the warranty period Danfoss shall offer a new compara-
ble product or repair the product in case the product is found to
be faulty by reason of defective design, materials or workman-
ship. The repair or replacement shall be carried out free of charge
providing that the warranty claim is valid.
The decision to either repair or replace will be solely at the
discretion of Danfoss. Danfoss shall not be liable for any
The Danfoss warranty is granted to:
Address
Product
Art. No.
Laying out Date
& Signature
Resistance [Ω]
Connection Date
& Signature
Resistance [Ω]
4
To get the full installation guide, warranty registration, prod-
uct information, tips & tricks, addresses, etc.
visit www.danfoss.com
and www.gb.fhemanuals.danfoss.com.
• Never exceed the maximum heat density (W/m) for the
actual application.
• Caution! Do not use M1 classified cables in areas subject to
high mechanical loads or impact.
The presence of a heating cable must
• be made evident by affixing caution signs in the fuse box
and in the distribution board or markings at the power
connection fittings and/or frequently along the circuit line
where clearly visible (tracing).
• be stated in any electrical documentation following the
installation.
• Free end from cold lead must be protected by installer to
avoid water from coming in.
nical damage according to IEC 60800:2009.
C — High mechanical strength according to IEC 60800:1992.
MMM — Marking for high mechanical protection class ac-
cording to NF C 32-330:2002
consequential or incidental damages including, but not limited
to, damages to property or extra utility expenses. An extension
of the warranty period following repairs undertaken cannot
be granted. The warranty shall be valid only if the WARRANTY
CERTIFICATE is completed correctly and in accordance with the
instructions, and provided the fault is submitted to the installer
or the seller without undue delay and proof of purchase is
provided. Please note that the WARRANTY CERTIFICATE must be
completed in English or local language.
Danfoss warranty shall not cover any damage caused by incor-
rect conditions of use, incorrect installation or if installation has
been carried out by non-authorized electricians. All work will be
invoiced in full if Danfoss is required to inspect or repair faults
that have arisen as a result of any of the above. The Danfoss
warranty shall not extend to products which have not been paid
in full. Danfoss will, at all times, provide a rapid and effective
response to all complaints and inquiries from our customers.
The warranty explicitly excludes all claims exceeding the above
conditions.
For full warranty text visit www.danfoss.com,
www.danfoss.com/en/warranty/
Stamp
Resistance [Ω]
Insulation [MΩ]
Insulation [MΩ]
VIAMT302
Installation Guide
Heating cables
6
Application overview
Cable type
ECflex 6T, ECflex 10T
M2
ECflex 18T, ECflex 20T
M2
ECflex 50T, ECflex 75T, ECflex 100T
M2
ECflex 30T
M2
ECfreeze 7,5T
M2
ECsafe 20T
M2
ECsafe 100T
M2
ECsnow 20T
M2
ECsnow 30T
M2
ECsnow 250T, ECsnow 300T
M2
ECsnow Drum
1)
M2
ECbasic 10S
C
ECbasic 20S
C
ECbasic Drum
1)
C
ECsport (DSM3)
1) 2)
MMM
ECmulti PVC (DMIH)
1)
M2
ECmulti HDPE (DMIT)
M2
1) 2)
ECasphalt 30T
M2
ECasphalt 300T
M2
ECaqua 9T
2)
M1
ECpipeheat 10
M2
1)
ECpipeguard
, EChotwatt
M2
1)
1)
ECiceguard
1)
M2
1) Heating cables/mats can be customized for the specific project, depending on voltage, required output, length of heating
cable and length of cold leads.
Note: It is the full responsibility of the installer/designer to use proper cold lead dimensioned for the purpose and assembly
sets that establish sufficient mechanical strength, flammability resistance and water tightness - and to design the heating
unit with correct output for the specific application to avoid overheating of the cable or building materials.
2) The heating cable shall only be installed in concrete or used while fully covered with non-flamable material eg. soil, water
or similar.
Regarding other types of applications please contact your local Danfoss sales company.
More information about applications can be found at www.danfoss.com
Applications
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
VIAMT302
EN
x
x
x
x
x
x
x
x
x
x
x
x
x
5

Publicidad

Tabla de contenido
loading

Tabla de contenido