Main Technical Features - Kübler CODIX 134 Instrucciones De Servicio

Contadores horarios con visualizador lcd
Ocultar thumbs Ver también para CODIX 134:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

• Signal levels do not reach the switching threshold of
the counter
If, despite all, your device still does not operate, contact
your local representative or call us directly for technical
support.
Overview
Model
Operating
mode
6.134.012.8x0
Timer
6.134.012.8x1
6.134.012.8x1
6.135.012.8x0
Timer
6.135.012.8x1
6.135.012.8x3
Table 1
DC operating modes:
Timer:
INP A:
no function
INP B:
Timer-Enable-Input

Main technical features:

Display:
LCD, 8 decades, height of the figures 8 mm
Display range:
0...99999999 with leading zeros
suppression.
Accuracy: < 100 ppm
Note:
For one ON/OFF-cycle the counter can lose
max. one impulse of the selected time range
Overflow: In case of a display range overflow, the timer
starts again from 0, but without removing
the leading zeros and activating all decimal
points.
Keys:
Electrical locking of the reset key
Housing: Panel mounting, 48 x 24 mm
according to DIN 43 700, RAL 7021
Panel cut-out:
22.2
+0,3
x 45
+0,6
Mounting depth:
approximately 48 mm
Weight:
approximately 50 g
Time range
99999h 59 m /
99999.99 h
9999 h 59 m 59 s /
9999999.9 s
mm
When sending your device back, please attach a short
description of the failure, of the programming and of the
connection diagram, in order to allow us to reproduce
a possibly existing defect and to repair your device as
quickly as possible.
Inputs
INP A
10...260 V AC/DC
AC/DC
10...260 V AC/DC
AC/DC
Options:
x = 5: no backlight
x = 6: with backlight
AC operating modes:
Timer:
INP A:
Timer-Enable-Input AC/DC
INP B:
reset input AC/DC
Protection level:
IP65 on the front side, device only
Connection:
Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1.5 mm
EMC:
Interference emissions
Interference resistance
Device safety (for the AC models):
Design to:
EN 61010 Part 1
Protection Class:
Protection Class 2 (front side)
!
Only the front side is classified as accessible
for the operator.
Application area:
Insulation: Front:
Rear side: basic insulation, Signal inputs
INP B
0...0,7 V DC
NPN
4...30 V DC
PNP
10...260 V AC/DC
AC/DC
0...0,7 V DC
NPN
4...30 V DC
PNP
10...260 V AC/DC
AC/DC
2 x 0.75 mm
AWG 26-14
EN 55011 Class B
EN 61000-6-2
Pollution level 2
over-voltage Category II
double insulation,
and und sensor power supply:
SELV
Page 3 | ENG