4.3.2) Programming of the closure torque reduction (RDC)
The torque reduction is a programmable function that prevents excessive tension on the fabric by reducing the pulling torque by approxi-
mately 50% just before the awning is fully retracted against the box.
Table "A5"
Programming the torque reduction (RDC)
Press and hold down button ■ of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button ■ for another 5 seconds until 4 rapid beeps are heard
2.
Press button ■ until 3 beeps indicate that the RDC function has been activated
3.
4.3.3) Cancellation of the positions or RDC function
To modify the previously memorised positions, they must firstly be cancelled and then the new positions programmed again.
Table "A6"
Cancellation of the intermediate position "I"
Press and hold down button ■ of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button ■ for another 5 seconds until 4 rapid beeps are heard
2.
Press buttons ▼ and ▲ together until 5 beeps are heard, indicating that the
3.
intermediate position has been cancelled
Table "A7"
Cancellation of positions "0" and "1"
Press and hold down button ■ of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button ■ for another 5 seconds until 4 rapid beeps are heard
2.
Press button ▼ until 5 beeps signal that positions "0" and "1" have been cancelled
3.
WARNING: After positions "0" and "1" have been cancelled the awning will move with hold-to-run and a new position needs to be memo-
rised.
Note: the intermediate positions "I" and the RDC function that are programmed are not cancelled. If you wish to cancel everything (including
the codes of the transmitters), refer to table "A10".
Table "A8"
Cancellation of the torque reduction function (RDC)
Press and hold down button ■ of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button ■ for another 5 seconds until 4 rapid beeps are heard
2.
Press button ■ until 5 beeps signal that RDC function has been deactivated
3.
Note: Now the awning will close at full force