4. WIRING DIAGRAMS

Terminal board for connecting mains
supply circuit and motor
fi g. 4.1
!
Warning
Connect Phase and Neutral Wire of the mains supply as shown in the picture.
Controls and available inputs
Local Open: connect the NO contact of a device such as a pushbutton used to send an open pulse to the
automation between terminals 6 and 2.
Local Close: connect the NO contact of a device such as a pushbutton used to transmit a close pulse to the
automation between terminals 5 and 2.
Stop: connect the NC contact of a device such as a red mushroom-head pushbutton with mechanical lock used to
stop the automation in an emergency between terminals 4 and 2.
Safety: connect the NC contact of a device such as a photocell between terminals 3 and 2.
In stand-by mode, this device stops the automation, while, during the closing phase, it reverses the motion
and prevents entrapment risks.
!
Warning
If you don't connect a Stop device you must jumper the terminals 4 and 2.
If you don't connect a Safety device you must jumper the terminals 3 and 2.
The appliance is equipped with output for powering accessories or safety devices with maximum
current consumption of 300 mA.
Information
The appliance comes complete with antenna. If the range is not suffi cient, an external
antenna can be connected to the special terminals as shown.
ENGLISH
Terminal board for connecting con-
trols and safety devices
fi g. 4.2

5. MEMORY MANAGEMENT

The information regarding remote controls and operation selections are stored in the module memory.
To restore the factory-set confi guration and erase all remote controls previously stored in the module memory,
proceed as follows:
Turn off the module.
Turn the module on again while holding the clear key SW3 pressed until the buzzer will turn off.
Wait about 10 seconds until the module beeps once signalling that the clearing phase is completed.

6. REMOTE CONTROLS MANAGEMENT

6.1 FIRST PROGRAMMING
Turn on the module and wait until it beeps once, then:
1. Press keys 1-4-5-8 simultaneously if you are using a TR14, or press all keys if you are using a TR2 or a TR4, until
a short beep followed by a continuous sound will be emitted: the learning phase is in progress.
Key 1
2. Now press any key on the transmitter: the buzzer will turn off for a short time, then turns on again to confi rm
that the remote control has been stored in the module memory.
After the fi rst learning, it is possible to store other remote controls by repeating steps 1 and 2 until the sound
alarm remains activated.
The learning phase ends either at the pressure of the clear key SW3 or automatically about 25 seconds
after the last storage.
When one or more remote controls are stored in the module memory, a signal transmitted by key
interpreted as a "Local Open" command, a signal transmitted by key
The appliance can also receive a Centralized Open, Centralized Close or Stop command via radio. These three
commands are not activated in the standard confi guration: to modify and/or complete the standard keys - RF
commands confi guration, read par. 9.
Information
To prevent an accidental programming, turn off other appliances within the range of the remote control you are
using if such appliances have still to be programmed.
Key 2
Key 1
Key 2
Key 3
Key 4
as "Local Close" command.
is
4
4