11. CENTRALIZED CONTROL - VIA RADIO

A more effi cient way to control more automations simultaneously, using the peculiar characteristics of the modules,
is programming them in order to receive centralized open and centralized close commands. In this way, you
get prioritized centralized commands as well as the possibility to simultaneously control more automations
individually and by group with one remote control.
Centralized commands have priority on local commands; for this reason, for the whole duration of the (opening or
closing) cycle controlled by a centralized commands, local commands are disabled.
Regardless of the operation logic selected, the reception of a centralized command causes the immediate
execution of the corresponding motion for the duration of the pre-set operating time.
"Stop" and "Safety" inputs remain always activated, thus enabling the user to stop or reverse the motion in
the event of dangers for people or property.
Example 1: individual or multiple control of two automations with one 4-key remote control.
Select the "step-by-step" logic for both modules and program the remote controls as follows.
Module 1
Assignments
Local Open
Local Close
Centralized Open
Centralized Close
Stop
Module 2
Assignments
Local Open
Local Close
Centralized Open
Centralized Close
Stop
Module 1
With these assignments, the transmitter
Control
will send the following commands:
Centralized
Opening
The easiest way to control more automatic systems via
radio is to store the same remote control in all modules
you wish to operate together. In this case whether
you add a remote control to the system, dedicated to
the simultaneous control or you lose the possibility
to control the automations individually. Additionally,
the commands transmitted by the dedicated remote
control will not have priority.
Key 1
Key 2
Key 3
Key 4
n.a.
Key 2
Key 1
Key 3
Key 4
n.a.
Module 2
Control
Centralized
Closing
Example 2: individual or multiple control of six automations (M1,M2,..,M6) with one 14-key remote control
(T1,T2,T3,..,T14).
Select the "Semiautomatic Open/Close" logic for all modules and program the remote controls as follows.
Radio commands
M1
M2
Local Open
T1
T3
Local Close
T2
T4
Centralized Open
T13
T13
Centralized Close
T14
T14
Stop
n.o.
n.o.
With these assignments, the transmitter will send the following commands:
Keys-Commands confi guration
Opening M1
Opening M3
Opening M5
M3
M4
M5
M6
T5
T7
T9
T11
T6
T8
T10
T12
T13
T13
T13
T13
T14
T14
T14
T14
n.o.
n.o.
n.o.
n.o.
Closing M1
Opening M2
Closing M2
Closing M3
Opening M4
Closing M4
Closing M5
Opening M6
Closing M6
Centraliz.
Centraliz.
Opening
Closing