9. RF COMMANDS PROGRAMMING

This programming can be done only after having turned the appliance off and on or at the end of a closing
cycle (end of the operating time).
To change the keys-RF commands confi guration, proceed as follows:
1. Press SW1 (RF commands programming key). The appliance beeps twice slowly signalling the beginning
of the programming phase.
2. Using an already programmed remote control, press in sequence the keys corresponding to the Local Open,
Local Close, Centralized Open, Centralized Close, and Stop commands; after every learning a number of beeps
equal to the number of already programmed commands will be emitted.
All the assignments are facultative. To skip a key position, press SW2 (times programming key) instead
of the remote control key.
3. At the end of the learning phase, the procedure ends automatically (two slow beeps will be emitted) and
you can return to normal mode.
Information
If you make a mistake (for instance more commands assigned to the same key), a number of short beeps will
be emitted at the end of the programming phase. In this case, it is possible to re-program the keys starting from the
one to which the "Local Open" command has been assigned.
If, after entering the learning phase, no key is pressed within 15 seconds, the procedure ends automatically
(time-out); any previous learning will remain valid.
If you make a mistake, quit the procedure by pressing SW1 (RF commands programming key): even in this
case any previous learning will remain valid.
If you want to change the parameters after the installation of the module and the latter is not easily accessible, the
procedure can be done via radio using an already programmed remote control.
a - Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or TR4) until hearing a short beep, then
release the keys.
b - Within 5 seconds, repeat the operation while holding the keys pressed until hearing two short beeps followed
by two long beeps signalling the beginning of the learning phase.
Now proceed as described above and remember that you have to press again keys 1-4-5-8 (TR14) or all
keys (TR2 or TR4) to skip a key position.
ENGLISH

10. TIMES PROGRAMMING

This programming can be done only after having turned the appliance off and on or at the end of a closing
cycle (end of the operating time).
In standard confi guration operating time and pause time are 45 seconds. These parameters satisfy most applications;
if they have to be changed, proceed as follows:
1. Press SW2 (times programming key 3) until hearing three long beeps: the programming phase is in progress.
2. Press the button or key of the remote control corresponding to the "Local Open" command: the countdown
starts automatically and one beep is emitted after every second elapsed.
3. Once reached the duration required for the operating time, press again the button or key of the remote
control; the countdown stops and the new setting is stored in the memory of the appliance which beeps
twice shortly to confi rm.
4. Repeat steps 2 and 3 for programming the pause time.
5. When both parameters have been programmed, the procedure stops automatically (three long beeps will be
emitted) and the appliance returns to normal mode.
Information
The pause time must always be programmed even if the selected logic is not the Automatic one: in this case,
the new setting will not affect the functioning.
If, after entering the programming phase, no key is pressed within 15 seconds, the procedure stops automatically
(time-out); any previous programming will remain valid.
If you make a mistake, quit the procedure by pressing SW2 (times programming key): even in this case the
previous programming will remain valid.
If you want to change the parameters after the installation of the module and the latter is not easily accessible,
you can proceed as mentioned above via radio.
A - Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or TR4) until the module beeps shortly,
then release the keys.
B - Within 5 seconds, repeat the operation until the module beeps twice shortly, then release the keys.
C - Again, within 5 seconds, repeat the operation and hold the keys pressed until hearing three short beeps
followed by three long beeps signalling that the programming phase is in progress.
Now proceed as mentioned.