Descargar Imprimir esta página

Eaton Night Falcon Instrucciones De Instalación página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

Yoke Mount (Figure 3.)
Tools Required
Torque wrench (ft-lbs) and 3/4" socket.
1.
Mount luminaire to surface using the hole pattern
provided on the yoke.
N
otee:
Hardware recommended 1/2" diameter bolt x 1-1/2"
long. (Supplied by others)
2.
Loosen but do not remove (2) center bolts. (Figure 3.)
3.
Rotate luminaire to desired aiming position and tighten
center bolts to 75 ft-lbs.
4.
Refer to wiring diagrams for power connection.
(Figure 4.)
Photocontrol – If Equipped (Figure 5.)
The orientation procedure is only required for
N
otee:
photocontrols which specifically require the cell to
be aimed north. Otherwise pre-selected factory
orientation will function properly. Follow the
directions recommended by the photocontrol supplier
for proximity to light sources. Lighted signs, building
surface reflection, floodlights, tree branches, etc.
may affect final position of the photocontrol.
1.
Using a flat blade screw driver, loosen the two flathead
screws to allow rotation of the receptacle.
2.
Insert screwdriver into center slot and rotate receptacle
until arrow points north or desired direction.
3.
Retighten screws.
4.
Insert the photoelectric control (or shorting cap) into
receptacle and twist into locked position.
N
otee:
The photocontrol (not included) must contain a soft,
resilient gasket fastened to the bottom surface to
assure a proper weather seal between the control
and the receptacle.
Installation Instructions – Night Falcon/UFLD
Figure 3.
(+) Line
(-) Common
Ground
Wiring Diagram
Figure 4.
Insert flat head
and rotate
Loosen screws
Figure 5.
EATON
IB506007EN
Mounting
Block
Center Bolt
Yoke Bracket
Black
White
Fixture
Green
Installation instructions
3