5. Operate the Steam Control
Steam Control Operation
NOTE: The clock is always displayed when the steam generator is not in use.
Press the "Power" button to start the steam generator.
When the "Power" button is pressed the green light on the button turns on. The light remains on
until the unit is turned off. The display reads "On" for the first 3 minutes of operation if the settings
are not changed.
Press the "Power" button again to turn off the steam generator. The green light on the "Power"
button will turn off and the display will read "Off" for 5 seconds, and will then return to display the
clock.
NOTE: When the unit is turned on, the steam duration and temperature settings will be those of the
previous user's settings. A new steam control unit comes pre-set to operate at 113°F (45°C) for 15 minutes.
Steam Control Operation
NOTE: Make sure the steam control unit is turned on before making any of the following adjustments.
Press the "Temperature" button and the display will flash the previous temperature setting. To
adjust the steam room temperature, press the "Increase" or "Decrease" buttons to raise or lower the
steam room temperature. The maximum allowable temperature is 125°F (52°C), and the minimum
operating temperature is 90°F (32°C).
After 5 seconds, the flashing will stop and the room temperature will be displayed as it changes to
the target temperature.
Press the "Timer" button and the display will flash the previous run time setting. Press the
"Increase" or "Decrease" buttons to adjust the time setting higher or lower. After 5 seconds the
flashing will stop and the timer setting will be displayed. If the "Increase" or "Decrease" buttons are
not pressed the time will continue to count down. The minimum operating time is 10 minutes, and
the maximum time allowed is 20 minutes.
Press the "Clock" button and the display will flash the currently set time of day. Press the "Increase"
or "Decrease" buttons to adjust the time of day. After 5 seconds the display will stop flashing and
the set time will be displayed.
Press the "Power" button to stop the steam generator and exit the steam room at any time. The
display will read "Off" for 5 seconds and then default to the set clock time.
Change the temperature reading between Fahrenheit and Celsius by pressing and holding the
"Temperature" button for 3 seconds.