Sharp AE-X2M20RU Manual De Instalación página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Connector
(Commercially
Expansion
Valve Angle
less than 3/8 in
Lock nut
(Commercially
available)
Hook
Insert the cable into Cable Holder
Caution:
• Be very careful not to confuse the terminal connections.
Wrong cabling may damage the internal control circuit.
• Be sure to connect the cable to match the markings on
the outdoor unit's terminal board and those of the indoor
unit.
• Be sure to put the cable leads deep into the terminal
board and tighten up the screws. Poor contact can
cause overheating of fi re, or malfunction.
• Be sure to use a disconnect switch. Follow the local and
state electrical codes.
5
POWER CABLING
Prepare a dedicated power supply circuit. For the connections, see below.
Supply power
Guaranteed voltage
Max. Fuse
Min. Circuit Ampacity
6
WIRE CHECK
Miswiring of connecting cable will be self-corrected by the
wire check operation.
(1) Turn the circuit breaker on.
(2) Check that all LED(LED1A, LED1B) on the display board are fl ashing
simultaneously.
If one or more of the LED is/are kept lit, check for mismatching terminal
markings ( , L1, L2, 2) and correct them.
(3) To start the wire check, press the WIRE CHECK button(SW2) for 5
seconds or more.
The operation lamp on the indoor unit will fl ash, and three BEEP will be
emitted.
All LED will fl ash rapidly.
(4) When wire check is completed normally, all LED will fl ash simultaneously
and the operation will stop. (Wire check time: 5 - 10 minutes)
When self-correction can not done, all LED will indicate triple fl ash for
eight times and the operation will stop. Check and correct following
points.
• Check all pipings are connected.
• Check the stop valves are open.
After correction, repeat the wire check again. If error is still detected, or other types
of LED signal should be indicated, please contact a service technician. (Refer to
wiring diagram attached inside the outdoor unit for self diagnosis signal.)
AE-X2M20RU_3_LANG.indb EN-4
AE-X2M20RU_3_LANG.indb EN-4
Conduit
available)
Wire Conduit
(Commercially
(10mm)
available)
Fig.3
Fig.5
208/230 V, single-phase
187-253 V
35 A
23 A
12.5 in (318mm)
15 in (380mm)
Indoor unit A
Indoor unit B
L1 L2 2
L1 L2 2
L1 L2 2
L1 L2 2
A
• Fit a disconnect switch, having a contact
separation of at least 0.12 inch (3 mm) in
all poles, to the electricity power line.
Note:
• Wire check may not be performed
when the outdoor temperature is
below 41 °F (5°C).
EN-4
Power supply Cable
Connection Cable
Fig.4
UNIT A
L1
2
L2
UNIT B
L1 L2
2
Fig.6
Disconnect
switch
Power Supply
208/230V 60Hz
Ground
L1 L2
B
Outdoor unit
SELECT
DSW1
LED1A
1
2
OFF
ON
LED1B
PUMP DOWN
SW1
WIRE CHECK
SW2
WIRE CHECK button (SW2)
2013-12-19 21:01:20
2013-12-19 21:01:20
L1 L2

Publicidad

Tabla de contenido
loading

Tabla de contenido