6. Wiring.
CAUTION: Be sure outlet box is properly grounded or that
a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to below, please use a qualified electrician.
Note: Excess lead wire length from the fan can be cut to
the desired length and then stripped.
WARNING: If using this fan in a DAMP location, this fan
must be connected to a supply circuit that is protected
by a Ground Fault Circuit Interrupter (GFCI) to reduce
the risk of personal injury, electrical shock or death.
When fan is secured in place on the hanging bracket,
electrical wiring can be made as follows:
Connect BLACK wire from fan to BLACK wire from
ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from
ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together from fan
to BARE/GREEN wire from ceiling with wire connector
provided.
Since this fan does not come with a light kit, you will
need to cap off the BLUE wire with a wire connector (as
shown with arrow in diagram). [Note: If you elect to
purchase a light kit for the fan, the BLUE wire from the
fan must be connected to the BLACK wire from the
ceiling instead.]
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
IN ORDER TO WIRE WALL CONTROL, remove existing wall
switch. Wire the WALL CONTROL with wire connectors provided
as shown in diagram at right.
* Wrap each wire connector separately with electrical tape as an
extra safety measure. Gently push wires and taped wire
connectors into outlet box.
WARNING: CONNECT WIRES IN THE FOLLOWING ORDER ONLY!
WARNING: Turn off circuit breakers to current fixture from
breaker panel and be sure switch is turned to the OFF position.
Connect GREEN ground wire to ground from house or directly
to one of the screws from the outlet box.
Connect one BLACK wire from wall control to BLACK (hot) lead
wire from house. Connect second BLACK wire from wall control
to BLACK load wire to fan.
Attach wall control to outlet box and secure with screws from
original wall switch. Attach front plate to wall control using 2
screws provided in the wall control.
white supply wire
black supply wire
from ceiling
black
white
white
black
blue
from fan
outlet box
(AC IN from
breaker box)
(wiring for wall control)
Modifications not approved by the party responsible for compliance
could void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
*
Reorient or relocate the receiving antenna.
*
Increase the separation between the equipment and receiver.
*
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
page 6
ground
(green or bare)
wire
connector
ground
(green
or bare)
*
wall
control
plate
green/
green/
green/
bare
bare
bare
ground
ground
ground
green
black (OUT to fan)
black
black
(TO POWER supply)
black