6.2 With the hidden key of a transmitter already learnt.
Always when the automation is still, press with the help of a clip the hidden key of a transmitter already learnt. The beginning of the learning proce-
dure is indicated by some long beeps at each second. Once entered into the learning stage follow the procedure mentioned at point 6.1.1 in case you
need to learn a two buttons transmitter or follow the procedure at point 6.1.2 in case you wish to learn a three buttons transmitter.
7. Selectable functions through dip-switch
It is important to change the configuration of the dip-switch only when the unit is
turned off!!! Turn off the power supply during the change of configuration.
Default settings
The control board is supplied with the dip-switches set as indicated in the Pict. 1. In the table are sum up the functions that can be selected through
these dip-switches.
Fig.1: factory setting
of the dip
7.1 Operating on opening/closing
This function enables to select the method of opening / closing of the automation.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
The functioning mode with "pulse functioning" activated can be selected by dip 4.
6-1622605
rev.0
07/05/2013
dip
1
Function on opening
2
Function on closing
3
4
Pulse functioning
5
6
Safety edge test
The automation works under dead man mode on opening.
The automation works under pulse mode on opening.
The automation works under dead man mode on closing.