Setup (con't)
1. Plug the machine in to 110 VAC, 15A
electrical outlet.
2. Check that the emergency stop is pulled out
(ready position).
3. Turn the Lockout switch (3) on.
4. Press the green start button and wait for the HMI
touch screen to display and the Green pilot light
to light.
Access Door
Refer to the "Identification" section of this manual.
The access door (8) has a safety interlock (12) on the
door handle that prevents the machine from running
with the door open. The safety interlock requires power
to unlock when the access door is closed. To open the
access door, perform the following:
1. Check that the machine is plugged in to 110 VAC,
15A electrical outlet.
2. Turn the Lockout switch (3) on.
3. Check that the emergency stop switch (2) is pushed
in (stop position).
4. Press and hold the yellow release button (4) and lift
the access door handle.
Note: there is a 60 second delay after the
emergency stop switch (2) is pushed (stop position)
before the access door can be opened. The delay
provides the sufficient time for the saw blades to
stop when a cutting cycle is interrupted. The HMI
screen will display "Safety Stopping..." at the top
of the screen during the delay and will display
"Machine Safe" when the access door can be
opened (see figures 4–6).
5. To close the access door, lower the door and
check that the switch key is fully engaged into
the interlock.
Greenlee Tools, Inc.
C3 Auto Whip Clad Cable Cutter
12
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Figure 4
Figure 5
Figure 6