Information on the charge indicator lamp
The charge indicator lamp 7 supplies the following information:
The charge indicator light 7...
Flashing red
Flashing green
Flashing alternately green/red
Lights up green
Installation of the wall bracket
DANGER – ELECTRIC SHOCK!
►
Ensure that there are no power cables or other conduits or pipes in the wall
at the location where you intend to bore the holes for the wall bracket 3 .
Drilling into a current-carrying electric cable can be potentially fatal!
1) Insert the barrel plug 5 on the mains adapter 4 into the wall bracket 3 as
shown in the following diagram:
First, feed the cable through the cable routing and then push the barrel plug 5
into the opening in the wall bracket 3 so that it is firmly in place . Secure the
barrel plug 5 by turning it .
2) Select a suitable installation location for the wall bracket 3:
It must be possible to remove the handheld vacuum cleaner easily and there
must be an accessible mains power socket for the mains adapter 4 .
3) Drill two holes about 60 mm apart . Use the wall bracket 3 to mark the holes,
to ensure the correct spacing . The drill holes must be suitable for 6 mm wall
plugs .
■
56
│
GB │ MT
Meaning
the batteries are charging .
the batteries are low and should be
charged soon .
the batteries are completely discharged
and should be charged .
the batteries are fully charged .
the appliance is in operation .
SAS 7.4 LI D3