Descargar Imprimir esta página

Samson PM35 Guía De Servicio Técnico Y Recambio página 4

Ocultar thumbs Ver también para PM35:

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
REPAIR AND CLEANING PROCEDURE
AIR DISTRIBUTOR
1. Unscrew the 4 bolts (2) from the cover (24) and remove it.
2. Unscrew the 4 bolts (2) from the cover (12) and remove it.
3. Gently strike the spool (18) with a plastic tool by its minor diameter side
(see fig. 7), through the motor, and remove the spool (18).
4. Replace the seals 4x14, 15 and 17 with new ones or replace the whole
spool (18) with its seals factory installed (kit 539505). This is strongly
recommended in order to ensure the correct assembly of the seals.
1
2
3
4
8
9
10
5
7
7
7
16
26
21
23
25
28
29
38
28
29
35
60
61
4
853 826 R. 06/17
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
12
6
AIR MOTOR SEALS (FIG. 8)
19
1. Remove the 3 bolts (2) and then the cap (1).
27
2. Remove the part (3) and its o-ring (4). Remove o-ring (4) and replace
7
it later by a new one.
3. Take away the 2 curved keys (8).
4. Unscrew the 5 bolts (10) and take tehm away along with their washers
(9).
5. Pull upwards the head of the motor (16) till it´s free from the rest of the
pump.
6. Pull upwards the part (5) till it´s out of the head of the motor. Remove
the o-rings (3x7 and 6) and replace them later by new ones.
7. Remove o-rings (21, 23, 26, 4x27) and the one (7) below the washer
(19). Replace them later by new ones.
8. Remove the 4 bolts (60), pull upwards the part (25) and then remove
o-rings (28) and (29). Replace them later with new ones.
9. Pull upwards the cylinder (38) and replace o-rings (28), (29) and (35).
10. Reassemble in reverse order, applying thread locker in part (3).
Note: all these seals are included in the available kit 539502.
Fig. 8
2
Fig. 7
14
15
17
24
18
2

Publicidad

loading

Este manual también es adecuado para:

535531535581535511