PROGRAMMING THE OPERATIONAL LOGIC

It is possible for the control unit to use several different operational logic states, by simply moving the dip-switches located on the card.
The functions associated with each individual dip-switch are listed below.
DIP
FUNCTION
1
Pre-flashing
Automatic
2
closure
3
Start opening
4
Operational logic
5
Slow down
6
Start off
7
Anti-slip
8
Photocell
9
Photocell test
Safety edge
10
type
11
Safety edge
12
Safety edge test
SETTING
DESCRIPTION
ON
Disabled
The blinker is switched on when the motor is started
OFF
Enabled
The blinker is switched on 2 seconds before the motor is started
The gate is closed automatically after the period of time set by the PAUSE
ON
Enabled
trimmer
On completion of the opening step, the gate remains open. It is necessary to
OFF
Disabled
instruct closure with another START command
ON
Not accepted
Any START command issued during opening is not heard
OFF
Accepted
Any START command issued during opening is accepted
Start during opening causes closure.
ON
Inversion
Start during closure causes opening.
Commands subsequent to starting cause, in order:
OFF
Step
open
At the end of each opening and closing step, the motor slows down in order to
ON
Enabled
avoid noisy closure and bouncing.
WARNING: With gates that are particularly heavy, or with high friction,
OFF
Disabled
breaking is not recommended, as it may lead to undesired stopping
ON
Disabled
At the start of each opening and closing step, the motor is started at maximum
power
OFF
Enabled
The time used for opening or closure will always be the value set by the WORK
ON
Disabled
trimmer, even if the previous operation has been interrupted before the expiry
of such time.
When an opening (or closing) operation is interrupted before expiry of the set
time (for example due to the intervention of one of the safety devices or due to
a start command), the duration of the subsequent closing (or opening)
OFF
Enabled
operation will not be that set by the WORK trimmer, but will be equal to the
time effectively elapsed, plus a short supplemental time in order to compensate
for the inertia of the gate.
Intervention of the photocell during opening or closing causes the gate to stop.
ON
Always active
When the photocell restores, the gate re-opens completely.
NOT active during
Intervention of the photocell during opening is ignored. Intervention of the
OFF
opening:
photocell during closing causes the gate to be re-opened completely.
The control unit performs a photocell operational test before starting each
ON
Enabled
opening or closing operation. If the photocells are not operating correctly, the
gate does not begin to move and the light flashes for approx. 8 seconds.
OFF
Disabled
PLEASE NOTE: connect the photocell TX correctly
Conductive rubber
Select this option if using conductive rubber edges with nominal resistance of
ON
edge
8K2.
Standard or optical
Select this option if using standard edges with switch normally closed or optical
OFF
edge
edges.
Intervention of the edge during opening or closing causes inversion of the
ON
Always active
direction of movement in order to free the body that caused the edge to
intervene. The gate will be stopped after approx. 3 seconds.
NOT active during
Intervention of the edge during opening is ignored. Intervention of the edge
OFF
opening:
during closing causes the gate to re-open completely.
The control unit performs an operational test on the edges before starting each
ON
Enabled
opening or closing operation. If the edges are not operating correctly, the gate
does not begin to move and the light flashes for approx. 8 seconds.
DO NOT enable testing if conductive rubber edges are used or standard
OFF
Disabled
edges are used without a suitable control unit for controlling function.
stop
close
stop...