Troubleshooting; Specifi Cations / Especifi Caciones - MasterCool MMB10 Manual De Instrucciones

Ocultar thumbs Ver también para MMB10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Problem
Possible Cause
Failure to
1. No electrical power to
start or no air
unit
delivery
• Fuse blown
• Circuit breaker
tripped
• Electric cord un-
plugged or damaged
2. Belt too loose or tight
3. Motor overheated
• Belt too tight
• Blower bearings dry
4. Motor locked
Inadequate
1. Insuffi cient air exhaust
air delivery
with cooler
running
2. Belt too loose
3. Pads plugged
Inadequate
1. Inadequate exhaust in
cooling
house
2. Pads not wet
• Pads plugged
• Open spots in pads
• Trough holes
clogged
• Pump not working
properly
Model
Modelo
MMB10
RMMB12
RMMB14
4

Troubleshooting

Remedy
1. Check power
• Replace fuse
• Reset breaker
• Plug in cords or
replace if damaged
2. Adjust belt tension
3. Determine cause of
overheating
• Adjust belt tension
• Oil blower bearings
4. Replace motor
1. Open windows or
doors to increase air
fl ow
2. Adjust belt tension or
replace if needed
3. Replace pads
1. Open windows or
doors to increase air
fl ow
2. Check water distribu-
tion system
• Replace pads
• Repack pads
• Clean trough and
unplug holes
• Replace or clean
pump
Specifi cations / Especifi caciones
Volts
Amperage
Voltios
Ameraje
Velocidad
115
4.7
115
8.1
115
10.7
Problem
Motor cycles
on and off
Noisy
Excessive
humidity in
house
Musty or
unpleasant
odor
Water drain-
ing from
cooler
Speed
Water Capacity (gal)
Capacidad de Agua (galón)
2
5
2
8
2
11
Possible Cause
Remedy
1. Low voltage
1. Check voltage
2. Excessive belt tension
2. Adjust belt tension
3. Blower shaft tight or
3. Oil or replace bear-
locked
4. Bearings dry
4. Oil bearings
1. Bearings dry
1. Oil bearings
2. Wheel rubbing blower
2. Inspect and realign
housing
3. Loose parts
3. Tighten loose parts
1. Inadequate exhaust
1. Open doors or win-
1. Stale or stagnate water
1. Drain pan and clean
in cooler
2. Pads mildewed or
2. Replace pads
clogged
3. Pads not wetting
3. Check water distribu-
properly
• Trough holes
clogged
• Pump not working
properly
1. Float arm not adjusted
1. Adjust fl oat
properly
2. Drain assembly leak-
2. Tighten nut and drain
ing
Weight (lbs.)
Peso (libras)
Dry
Seco
78
96
150
ings
dows
pads
tion system
• Clean
• Replace or clean
pump
cap.
Operating
Lleno
120
162
242
110522-2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rmmb12Rmmb14

Tabla de contenido