Electrical connections

Active unit

1
Pin
Wire
Function
RESET/
2
1
White
ACKNOWLEDGE/
RESET MODE
2
Brown
Supply
2
3
Green
EDM SELECTION
4
Yellow
EDM
5
Grey
OSSD1
6
Pink
OSSD2
7
Blue
Supply
8
Red
Earth
1
Colors according to ABB Jokab Safety standard cables.
2
The "RESET/ACKNOWLEDGE/RESET MODE" wire, the "EDM SELECTION" wire and the supply wires MUST be connected in order
for the device to function. The other wires may be floating.
2TLC172295M0201 Rev A
2015-03-20
Auto. Reset with no function
Auto. Reset with Acknowledge
function or Alignment mode
Manual Reset
Activate EDM
Deactivate EDM
Function used/activated
Function not used/deactivated
3
Connection to
+24 VDC
NC contact to +24 VDC
NC contact to 0 V
+24 VDC
Not connected or 0 V
+24 VDC
NC contact of force-guided relay
Not connected or 0 V
Safety control module for ex.
Safety control module for ex.
0 V
Earth