7 OPERATIONAL START-UP

7.1 CHECKING THE LEDS

< (1)
BUS
< (2)
< OPEN A
< GND
< OPEN B / CLOSE
< STOP
/ SAFE
< FSW OP
< GND
< FSW CL
< +24
Tab. 3 - Description of POWER LED
Fixed ON
Flashing
Off

7.2 BATTERY OPERATION

ATTENTION
" "
E721
LED
ON
2EASY
< SAFE
RADIO XF
LED
OFF
The STOP (SAFE), FSW CL, FSW OP , OPEN B inputs
configured as SAFE are safety inputs with N.C.
(Normally Closed) contact and therefore the
corresponding LEDs must be ON when the
automated system is at rest, and off when
the connected device is used.
The OPEN A, OPEN B/CLOSE inputs are inputs
with N.O. (Normally Open) contact and
therefore the corresponding LEDs must be
OFF when the automated system is at rest,
and on when the connected device is used.
When using equipment programmed as
SLAVE the LEDs corresponding to terminal
board J13 must be off.
ERROR LED flashing indicates alarm in
progress (situation does not impair gate
operation)
ERROR LED on with a fixed light indicates
an error in progress (situation that locks
operation until the cause of the error has
been removed)
14
F
-
+
SETUP
USB
OUT
- +
532014 - Rev. D