Menu screen
Original PIN: 0105
1
Reset settings
2
Station Settings
3
Program Settings
4
Counters
5
Program version
S e t t i n g s
1 Temp unit
Celsius
2 Maximum temp 450
C
0
3 Minimum temp
T OFF*
4 Fix temp
400
C
0
5 Temp Adjust
0
C
0
6 Max air
100%
7 Min air
10%
8 Fix air
40%
9 Time to stop
120 sec
10 Beep
ON
11 Pop up
ON
12 Change PIN
B a c k
* Selecting Minimum Temp to
"T OFF" allows for blowing at
ambient temperature.
1
Station ON hours
2
Works hours
3
Works cycles
14
M a i n m e n u
E x i t
P r o g r a m S e t t i n g s
1
Programs
2
Edit program
3
Copy program
4
Delete program
E d i t P r o g r a m
º
C
S e l e c t
P r o g r a m
8
E d i t P r o g r a m 8
º
C
S t e p
T i m e
T e m p
A i r
E x i t
C o u n t e r s
0
0
0
B a c k
JT-TA Replacing the Heating Element
Only perform this operation when the element is cold and the unit is disconnected from the mains.
1. Loosen the screw.
2. Pull the heating element away from the handle.
3. Connect the new heating element, ensuring its pushed all the way in.
4. Tighten the screw.
JT-TA Changing the Heater Hose Set
1. Ensure that the tool is turned off.
4
2 0
2. Use a spanner to unscrew the connecting nut.
4 5 0
3. The tube end of the new heater must be inserted
1 0 0
so that the longitudinal rib fits into the groove.
5. Follow the same steps conversely.
Heating Element
Ref. 0014107 (230V)
0014105 (100V / 120V)
Handle
Ref. 0009829
Heating Hose Set
Ref. JT-T1A (100V / 120V)
w w w.jbctools.com
JT-T2A (230V)
15