To Operate The User Interface; Before Operation; To Fix The User Interface To The Wall; To Insert The Batteries - Daikin FTXP20M5V1B Manual De Funcionamiento

Ocultar thumbs Ver también para FTXP20M5V1B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46

3 Before operation

Icon
Airflow rate = Indoor unit quiet
Airflow rate = High
Airflow rate = Medium high
Airflow rate = Medium
Airflow rate = Medium low
Airflow rate = Low
Comfort operation is active
Automatic vertical swing is active
Automatic horizontal swing is active
ON timer is active
OFF timer is active
2.2.3

To operate the user interface

a
Signal receiver
1 Aim the signal transmitter at the signal receiver on the indoor
unit (maximum distance for communication is 7 m).
Result: When the indoor unit receives a signal from the user
interface, you will hear a sound:
Sound
Beep-beep
Beep
Long beep
3
Before operation
3.1

To fix the user interface to the wall

a
b
c
a
User interface
b
Screws (field supply)
c
User interface holder
1 Choose a place where the signals reach the unit.
2 Attach the holder with screws to the wall or a similar location.
3 Hang the user interface on the user interface holder.
Operation manual
4
Description
a
Description
Operation starts.
Setting changes.
Operation stops.
3.2

To insert the batteries

The batteries will last for about 1 year.
1 Remove the back cover.
2 Insert both batteries at once.
3 Put the cover back.
1
3
2
AAA.LR03
3.3
To switch between Fahrenheit and
Celsius
Prerequisite: Change this setting only when the temperature is
displayed.
1 Press
and
simultaneously for about 5 seconds.
Result: The setting changes.
3.4

To turn on the power supply

1 Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the
reference position.
4

Operation

4.1

Operation range

Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~46°C
▪ Indoor temperature: 18~32°C
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –15~24°C
▪ Indoor temperature: 10~30°C
(a)
Drying
▪ Outdoor temperature: –10~46°C
▪ Indoor temperature: 18~32°C
▪ Indoor humidity: ≤80%
If operated outside the operation range:
(a)
A safety device might stop the operation of the system.
(b)
Condensation might occur on the indoor unit and drip.
4.2

When to use which feature

You can use the following table to determine which features to use:
Feature
Basic features
To start/stop the system and to set the
Operation modes and
temperature:
temperature
▪ Heat up or cool down a room.
▪ Blow air in a room without heating or
cooling.
▪ Decrease the humidity in a room.
▪ In Automatic mode, automatically
select an appropriate temperature
and operation mode.
Operation range
Tasks
FTXP20~35M5V1B
R32 split series
3P520336-6B – 2018.12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ftxp25m5v1bFtxp35m5v1b