setpoint's state.
Fan Minimum Run Time – Sets the amount of time the fan will have to stay
running before being allowed to shut-off if the compressor stops. Note that
this means the fan may continue to run after the compressor main motor has
stopped.
PORO Installed (ON/OFF) – Allows the PORO and Scheduled Start/Stop
functions to be turned ON. This can only be turned ON if the PORO kit has
been purchased and installed.
Running Hours (adjustable) – Used to adjust the running hours counter on
the compressor.
Power ON Hours (Read Only) – Displays the amount of time the controller
has had power connected.
Pages 5 Through 8 – Maximum Values
Figure 122 : Factory Settings (Maximum Values)
The maximum values pages are used to record the highest value the
controller has seen since the last time the maximum values have been reset.
Each maximum value entry displays the highest value recorded as well as the
time and date stamp of when these maximum values have occurred.
The fi nal maximum value page has a reset setting at the bottom of the page,
highlighting this button and hitting enter will cause the controller to clear all
history of maximum values and begin recording them again. The password
must be entered in order to use this reset functionality.
EN-54
Pages 9 & 10 – VSD Diagnostics
Figure 123 : Factory Settings (VSD Diagnostics)
The VSD Diagnostics screens are used to troubleshoot any drive problems.
These screens must only be used by authorized service technicians. The
password must be entered in order to activate these diagnostic tests.
Pages 11 through 14 – VSD Service Menus
Figure 124 : Factory Settings (VSD Service Menus)
The VSD service menus contain parameters used to set up the compressor for
optimal operation. The default selections have been set to work optimally for
a majority of compressors. These screens must only be used by authorized
service technicians. The password must be entered in order to modify these
parameters.
Pages 13 & 14 – Software Information
Figure 125 : Software Information
These pages are used for displaying software information for the controller.
All items are read only.