Diode Test

Range
Diode
Remark:
Open circuit voltage approximate 1.48 V
Displays approximate forward voltage drop: 0.5 V ~ 0.8 V
F.

Capacitance

Range Resolution
4 nF
40 nF
10 pF
400 nF
100 pF
4 µF
40 µF
10 nF
200 µF
100 nF
Remark:
40 nF ~ 200 µF: Reading <1nF is only for reference purpose.
G.
Frequency & Duty Cycle
Range
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
0.1%~99.9%
Remark:
10 Hz ~ 10 MHz Range: Input sensitivity as follows: 1 MHz: 300
mV rms; >1 MHz: 600 mV rms. 0.1% ~ 99.9%: Reading is only for
reference purpose.
H.

AC Current

Range
Resolution
400 A
1000 A
Remark:
Frequency response: 50 Hz ~ 60 Hz Display effective
value of sine wave (mean value response).
44
Resolution
1 mV
1 pF
Measure at REL mode ± (5%+40)
1 nF
Resolution
1 pF
10 pF
100 pF
1 nF
10 nF
100 nF
0.1%
Accuracy
0.1 A
± (1.5%+5)
≤ 800 A: ± (1.5%+5)
1 A
>800 A: ± (3%+5)
Overload Protection
Accuracy
± (3%+5)
± (4%+10)
Accuracy
± (0.1%+3)
600 Vp
Overload Protection
600 Vp
Overload Protection
600 Vp
Overload Protection
1000 A rms contiuous