PUMP
***Make sure to have at least 1 inch [25MM]
of clearance from the sensors on the Ultima
Bilge pump to any wall or souroundings. If
there is not enough clearance, the sensors
may detect the object and leave the pump
running continuously.***
Maintenance:
The Ultima bilge pump is designed to be
worry free and maintenance free. How-
ever, care should be taken to make sure
that the impeller is clear of debris for opti-
mum pump functionality. Make sure power
is disconnected during maintenance of
the pump. To access the impeller, remove
pump from strainer by depressing the side
lock tabs on pump body and pulling pump
from strainer. To clean the impeller, grab
on to impeller guards fins and rotate im-
peller guard clockwise and pull straight
out. Remove and clean the impeller and
pump from all debris that has accumu-
lated. Make sure to clean any debris that
has accumulated on the strainer as well.
After the impeller is clean, replace impel-
ler guard by aligning tabs with slots and
turning counter-clockwise, making sure
not to over tighten. The guard should be
rotated until it is firm. Place pump body on
to strainer making sure that both locking
tabs snap onto pump body.
Original instructions
Black to negative(-)
Brown to positive (+)
(Manual override)
Brown/white to positive (+)
(Automatic operation)
Depress
(2) tabs
Warranty Information
Johnson Pumps of America of 10509
United Parkway, Schiller Park, Illinois
60176 warrants to the original consumer
purchaser that this product will be free
from defects in material and work manship,
providing that the case is not opened or
the pump other wise abused for a period
of three (3) years from the date originally
purchased.
> English
Lock impeller guard
by twisting counter
clockwise
9