Function menu setup
Function menus allow selecting a function from among a group
of available options. When you enter into a function menu, the
current active option will be viewed; pushing the programming
wheel upwards or downwards it is possible to scroll down the
available options. The displayed option is started up pressing
the wheel; after this, back to the configuration menu.
Time menu setup
Time menus allow setting a function duration. When you enter
into a time menu, the current setup value will be viewed; the
display mode depends on the current value:
• times being lower than one minute will be viewed as follows:
Every time the wheel is pressed upwards (UP) the set time
increases of half a second; every time it's pressed downwards
(DOWN) the time decreases of half a second.
• Times between 1 and 10 minutes will be viewed as follows:
Every time the wheel is pressed upwards (UP) the set time
increases of 5 seconds; every time it's pressed downwards
(DOWN) the time decreases of 5 seconds.
• Times being more than 10 minutes will be viewed as follows:
Every time the wheel is pressed upwards (UP) the set time
increases of half a minute; every time it's pressed downwards
(DOWN) the time decreases of half a minute.
Keeping the wheel upwards (UP) the time increases quickly,
until reached its maximum. Likewise, keeping the wheel
downwards (DOWN) the time decreases quickly, until reached
0.0"
In some circumstances, setting the value to 0 means that the
relevant function is disabled, in this case, 'no' will appear
instead of 0.0".
The displayed option is confirmed pressing the wheel (MENU);
after this, back to the configuration menu.
Value menu setup
Value menus are similar to time menus; however, the setup
value can be any number. Keeping the wheel pressed upwards
or downwards the value increases or decreases slowly.

QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control
unit and set it at work immediately. We recommend following
these instructions, in order to check quickly the correct
operation of control unit, motor and accessories, and then
changing the configuration in case of any non-satisfactory
parameter. Please refer to the paragraph "Control unit
configuration" for the item position inside the menu, as well as
for the available options for each item.
1. Call up a default configuration (item dEF.).
2. Set items StoP, Foto, CoSt and FC.En according
to the safety devices installed on the gate.
3. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store
set up parameters.
Self-learning procedure:
• In case the end of stroke or the obstacle sensor has been
enabled, the gate will be activated in closing direction until
the stop end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor
have been enabled, be sure that the gate is completely
closed when the procedure is started up.
• The gate will be activated in opening direction until the stop
end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command when the gate reaches its
max. opening position.
• The gate will be activated in closing direction until the stop
end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command must be sent when the gate
reaches its fully closed position.

CONTROL UNIT CONFIGURATION

This paragraph concerns the step-by-step procedure to set all
operation parameters of 900CT-101 control unit. You can
either follow all procedure steps and perform a complete
control unit configuration or select and adjust interesting items
only. As for both cases, you will have to perform the right exit
procedure through item FinE, in order to activate your new
configuration.
900CT-101 control unit provides for a self-learning procedure
of working times; therefore, we recommend that you set up a
standard configuration first (see previous paragraph), then you
carry out the self-learning and finally you change any
unsatisfactory items.
24