Default value loading
The value of all menu items can be brought to a standard value (see
final recap table) by means of only one command. There are two sets
of values available:
no
keeps the previous configuration (if the control unit is new, the
data are the default ones)
Si
upload default values
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
Opening time
The motor will be operated for the setup time in the opening phase;
in case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will
open the gate only, for a shorter time. Max allowed time to be setup is
t.AP.
Closing time
The motor will be operated for the setup time in the closing phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
To avoid that the gate does not close completely, we recommend to
setup a longer time than t.AP opening time.
Partial closing time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will use
this time to close the gate. Max allowed time to be setup is t.CH1.
To avoid that the door does not close completely, we recommend to
setup a longer time than t.APP opening time.
25