Pre-blinking time
Before any gate movement, blinker will be activated for t.PrE time, to
warn about the incoming motion.
Motor power
This menu allows adjusting the motor power.
The displayed value is the percentage of max. motor power.
Start off
When the gate is standstill and it begins moving, the initial inertia
must be faced, therefore, if your gate is quite heavy, it could not move.
In case the SPUNTO (pickup) function is activated, for the first 2
seconds of motion of each door, the control unit will ignore Pot value
and it will give motor the maximum power command in order to
overcome the gate inertia.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of
the gate, the control unit will give motor a reduced power command,
for a softer start.
Slowing down time
In case this function is enabled, during the last seconds of motion, the
control unit will give motor a reduced power command, to avoid a
strong impact with the stop end. t.AP is the max. allowed time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to
measure both opening and closing times, and to enable it again
once the setup has been carried out. The control unit will
automatically consider the working time delay caused by the
slowing down.
• If partial opening time t.APP is shorter than t.AP, there will be no
slowing down during the pedestrian cycle opening.