ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK
9. Remove cover from pressure switch and
screw the switch into the 1/4 in. opening on
the top of the pipe tee. (Fig. 9)
10. Thread the cable from the house electrical
service through one of the holes in the side
of the pressure switch and tighten down
the electric wire strain relief.
CAUTION: Do not crush wire. (Fig. 10)
1. Connect the two wires from the house
electrical service to the outside pressure
switch terminals (L1 and L4). (Fig. 11)
25
Copyright © 2011 Star Water Systems. All rights reserved.
9
10
L1
L4
11
L1
L4
Strain Relief
IL1162
L1
L4