Electrical Hookup From The House To Pump And Pressure Tank - Star 4H05A05001 Manual Del Usuario

Bomba para pozos sumergible de 10,16 cm
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK

For - 2-Wire Pumps - No Control Box Required.
WARNING: This equipment is intended for installation by a technically qualified electrician.
Failure to install it in compliance with national and local electrical codes may result in electrical shock
or fire hazard, unsatisfactory performance, and equipment failure.
WARNING: Always disconnect power source before working on or near the pump, its
connected load and wiring. If the power disconnect is out of sight, lock it in the open position and
tag to prevent unexpected application of power.
1. Determine proper voltage from breaker box
(sold separately) to pressure switch. (Fig. 1)
2. Remove cover from pressure switch and
screw the switch into the 1/4 in. opening on
the top of the pipe tee. (Fig. 2)
19
Copyright © 2011 Star Water Systems. All rights reserved.
1
2
IL1170