Part 2
To convert the appliance to another type of gas, e.g. from natural gas
to LPG, the nozzles of the main burner, by-pass and pilot light have
to be changed. All the nozzles are marked with a number that
indicates the diameter in 1/100 of a mm and are supplied in a bag.
Connection to the distribution network, installation, and maintenance of the appliance must be carried out by qualified
technicians only, in observance of all applicable regulations!
BURNER:
1.
Pull the knobs off .
2.
Remove the control panel by unscrewing the fixing screws
placed at its lower part.
3.
Replace the nozzle "U" (pic. 2) with a suitable one for the new
type of gas indicated in the "MAX" nozzles table T1 section
Specifications.
BURNER:
7.
Pull the knobs off.
8.
Remove the control panel by unscrewing the fixing screws
placed at its lower part. .
9.
Replace the nozzle "U" (pic. 2) with a suitable one for the new
type of gas indicated in the "MAX" nozzles table T1 section
Specifications.
ADJUSTING THE AIR:
10. Loosen the fixing screw "X" (pic. 2)
11. Adjust the primary air by moving the bracket "S" (pic. 2) up to
the distance "H" indicated in nozzles table T1section
Specifications.
Screw the fixing screws in.
Cooktop burner, nozzles and air adjustment
Solid top burner (models PP../PCP..)
GB / IE - 3
Transformation and adaptation
After each transformation or adaptation, the unit must undergo an
operating test and the supplementary plate must be updated
according to the conversion or adaptation carried out.
ADJUSTING THE AIR:
4.
Loosen the fixing screw "X" (pic .2)
5.
Adjust the primary air by moving the bush up to a distance "H"
indicated in nozzles table T1section Specifications.
6.
Screw the fixing screws in.
PILOT FLAME:
12. Unscrew the closing nut "Z" (pic. 2).
13. Unscrew and replace the pilot nozzle "D" (pic. 2) with a suitable
one for the new type of gas indicated in the nozzles table T1
section Specifications.
14. Replace and tighten the closing nut.
MINIMUM:
15. Unscrew and replace or adjust the minimum by-pass nozzle
"Um" (pic. 2) on the basis of the indications in the nozzles table
T1 section Specifications.
16. Remove the control panel.
17. Replace the knob.
5410.290.00