General Instructions; Unit Characteristics - Tecnoinox PC 4 G9 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Part 1
GAS RANGES
The appliance described in this manual has been built in compliance
with the UNI EN 203, UNI EN 437, EN 60335-1, EN60335-2-36 and
EN55014 standards.
This appliance has been designed exclusively for cooking food, any
other use is considered improper. It is meant to be used by qualified
personnel in professional kitchens.
The appliance should be installed under an extractor hood for removing the cooking fumes.
Care must be taken when using the appliance because the cooking surfaces are very hot.
In the models PP.. and PCP.., the plate can reach the maximum temperature of 420°C.
The appliance must be installed, connected and serviced properly by qualified personnel according to the regulations and directives in
force in the country where it is installed, in compliance with the instructions included in this manual.
These installation and user's instructions manual refers to the
category II2H3+ gas ranges.
The self-adhesive polyester data plate "T" (pic. 1) is behind the
control panel (inside the appliance).
It contains the following information:
Modell
Serial number
Category
Year of manufacture
Nominal thermal capacity
Type of construction
Test base
G30
28-30/37 mbar
Connection pressure
G20
20 mbar
G30
0.83 Kg/h
Consumption
G20
1.11 m
Install a shut-off cock in the line between the appliance and the gas distribution network. Install an omnipolar switch between
the appliance and the electrical distribution network.
Before you install the appliance, make sure that the gas
company has authorised the installation. Then,
compare the relevant data of the appliance (data plate)
with the local supply.
Remove the packaging from the appliance as well as the protective
plastic sheet, and, if necessary, remove traces of glue with a suitable
solvent. To dispose of the packaging, follow local directives (for more
details refer to the chapter "ECOLOGY AND THE ENVIRONMENT".
Prior to connecting the unit to the gas network, check the data plate
and be sure that the unit has been set and tested for the type of gas
supplied. If the type of gas indicated on the data plate is not the
same as the one supplied, please refer to the paragraph
"CONVERSION AND ADAPTATION".
To connect the appliance to the gas distribution network, metal
pipes with a suitable diameter must be used; install a homologated
shut-off cock between the appliance and the distribution network. If
flexible pipes are used, they must be made of stainless steel
according to the standards in force. When installing the appliance, all
the regulations in force must be observed, such as:
UNI-CIG 8723 safety standard, Act n. 46 of March 5th 1990 and
circular n.68.

General Instructions

Unit characteristics

PC_4_G9
xxxxxx
II2H3+
xxxx
14.5 kW
A1
UNI EN 203-1
/h
3
Connection to the gas distribution network
The unit must never be left unattended when it is being used! The
appliance should be checked once a year by a qualified technician.
Switch the appliance off in the case of a failure or malfunction.
The supplementary plate is also made of self-adhesive polyester and
is affixed near the data plate; it contains all the information regarding
the presetting of the appliance.
The "G" gas distribution network fitting (pic.1) meets ISO 7/1 and
ISO 228/1 (DK) standards with a ø ½" or a ¾'' connection, situated
on bottom of the machine.
The appliance is made of stainless steel, the burners are made of
cast iron and the plate is made of stainless steel. All models have
adjustable feet.
The main gas pipe is made of galvanised steel. The pipes between
the tap and burner are made of copper.
Regional and/or local regulations, such as building codes;
Directives and regulations of the electricity board.
Accident prevention regulations in force;
Fire prevention regulations;
Applicable I.E.C. regulations.
We recommend installing the appliance in a well-ventilated
environment, or under an extraction hood to remove the fumes or
vapours produced during the cooking cycle.
All the models have an equipotential earth terminal "N" (pic.1) on the
bottom.
The appliances featuring an electric oven have a hole for the cable
"Q" (pic .1).The appliance can be installed alone or in line. Respect a
minimum distance of 80mm between the appliance and any wall
made of flammable material, partitions, kitchen furniture or nearby
equipment.
The contact surfaces must be covered with non-combustible heat
insulating material.
The appliance must not be installed near heat sources and the
temperature of the place in which the appliance is installed must not
exceed 50°C.
GB / IE - 1
Installation
5410.290.00

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pf 8gg9313001

Tabla de contenido