COOKTOP BURNERS
Press and turn the knob (pic. 1)" from position " " to " " keeping it
pressed in.
With the igniter "W" (pic. 1) or a match, light the flame.
After the flame has lit, hold the knob down for roughly 10 seconds
(count to 20); so the thermocouple heats up and keeps the safety
valve open.
HOT PLATE
In the models with a hot plate, lift the cover "C" (pic. 1) and follow the
previous instructions.
For the models PP../PCP.. light the pilot by pressing igniter button
"B" repeatedly (pic.1).
NOTE: if the piezoelectric device cannot be used, you can light the
flame by using a match or a gas lighter.
Turn off the gas shut-off cock installed upstream of the appliance.
Malfunctions are not always caused by the quality of the components
used. These appliances are manufactured using top quality
components. Failures may be caused by dust and dirt in the
operating components.
Unauthorised persons should never attempt to repair the appliance or carry out maintenance. Tampering with the appliance
voids the warranty!
Before the unit is delivered to the user, the following checks must be
carried out.
THERMAL CAPACITY
Check that the type of gas supplied and the pressure correspond to
the ones indicated on the plate. If they don't, the unit must be
converted or adapted. In this case please refer to the paragraph:
"Conversion or Adaptation".
Check that the right nozzles have been installed.
Refer to the nozzle table T1 section Specifications and check that
the nozzles indicated in the table are the same as those installed on
the unit.
For an additional check of thermal capacity, verify the gas
consumption by means of the volumetric method: light the burner
and after approximately 10 minutes (operating conditions) check that
the gas flow (in m
/h or in kg/h) corresponds to the one indicated in
3
nozzle table T1 section specifications.
Turning the burners on and off
What to do if the unit is not going to be used for a long time
Operational checks
To light the main burner, turn the knob to the desired position,
following the values in the table below:
Off
TURNING THE BURNER OFF:
Turn the knob from the current position to the " " position.
TURNING THE APPLIANCE OFF:
Turn the knob to the "
Clean the unit thoroughly following the instructions and dry it
carefully.
Malfunctions
In any case, if you suspect the presence of anomalies, ALWAYS
CLOSE the gas shut-off cock and inform the authorised after-sales
service.
APPEARANCE OF THE FLAME AND PRIMARY AIRFLOW
The flame should be blue and there should be no yellow dots in it; it
must be stable at its base.
If the colour of the flame tends to be yellowish , it means that the
primary airflow is not adjusted properly. If there's too much primary
air, the flame will be short and will tend to burn above the burner.
The appearance of the flame must also be checked 15 minutes after
the appliance has been running at full power. The flame must remain
stable even when passing quickly from minimum to maximum.
INSTRUCTIONS FOR THE USER
The user must be trained on the correct use and functions of the
appliance. We would like to point out that any alterations made in the
room where the unit is installed could influence the amount of air
used for combustion: for this reason the function of the unit must be
checked again. When these checks have been done, test the unit for
leaks.
GB / IE - 4
Pilot flame on
Burner MAX
" position.
Use
Burner min
5410.290.00