Maintenance
Hot oil may cause burns. Allow engine to
cool before draining oil. Avoid prolonged
or repeated skin exposure with used oil.
Thoroughly wash exposed areas with soap.
Whenever possible, run engine for approximately five (5)
minutes to get the engine oil hot. This will aid in draining the oil.
Use the following instructions to change the oil while the engine
is still warm:
• Clean area around oil drain plug.
• Remove oil drain plug from engine and oil fill plug to drain oil
completely into a suitable container.
• When oil has completely drained, install oil drain plug and
tighten securely.
• Place a suitable container beneath the oil filter and turn
filter counterclockwise to remove. Discard according to local
regulations.
• Coat gasket of new filter with clean engine oil. Turn filter
clockwise until gasket contacts lightly with filter adapter. Then
tighten an additional 3/4 turn.
• Fill oil sump with recommended oil. (See "Before Starting the
Generator" for oil recommendations).
• Wipe up any spilled oil.
• Dispose of used oil at a proper collection center.
3.3.6 REPLACING THE SPARK PLUG
Use Champion RC14YC spark plug or equivalent. Replace the
plug once each year. This will help the engine start easier and
run better.
1. Stop the engine and pull the spark plug wire off of the spark
plug.
2. To gain access, remove the four (4) Torx screws "T27" and
take off side panel.
3. Clean the area around the spark plug and remove it from the
cylinder head.
4. Set the spark plug's gap to .76 mm (0.030 in.). Install the
correctly gapped spark plug into the cylinder head (Figure 14).
5. Push the boot firmly on the spark plug and install side panel.
Figure 14 - Spark Plug Gap
12
NOTE:
3.4 SERVICE AIR CLEANER
The engine will not run properly and may be damaged if using a
dirty air cleaner. Clean or replace the air cleaner paper filter every
200 hours or once a year (Figure 15). Clean or replace more often
if operating under dusty conditions.
To clean or replace paper air filter:
• Remove air cleaner cover; then remove foam pre-filter (service
if necessary) and remove paper filter.
• Clean paper filter by tapping it gently on a solid surface. If the
filter is too dirty, replace it with a new one. Dispose of the old
filter properly.
• Clean air cleaner cover then slip pre-cleaner over filter. Next
insert new paper filter into the base of the air cleaner. Re-install
air cleaner cover.
To order a new air filter, please contact the nearest authorized
service center at 1-888-775-6937.
Figure 15 - Air Cleaner
BASE
FILTER
3.5 CLEAN SPARK ARRESTOR SCREEN
The engine exhaust muffler has a spark arrestor screen. Inspect
and clean the screen at least once each year (Figure 16). If unit is
used regularly, inspect and clean more often.
If using the generator on any forest-covered, brush-covered
or grass-covered unimproved land, it must equipped with a
spark arrestor. The spark arrestor must be maintained in good
condition by the owner/operator.
Clean and inspect the spark arrestor when the engine is at
ambient temperature as follows:
• Remove muffler heat shield from muffler by removing the four
screws.
• Remove spark arrestor from muffler by removing the four
screws.
NOTE:
COVER
NOTE: