3.3.2 TO CLEAN THE GENERATOR

Use a damp cloth to wipe exterior surfaces clean.
A soft, bristle brush may be used to loosen caked on dirt, oil,
etc.
A vacuum cleaner may be used to pick up loose dirt and
debris.
Low pressure air (not to exceed 25 psi) may be used to blow
away dirt. Inspect cooling air slots and openings on the generator.
These openings must be kept clean and unobstructed.

3.3.3 ENGINE MAINTENANCE

When working on the generator, always disconnect
negative cable from battery. Also disconnect spark plug
wire from spark plug and keep wire away from spark
plug.

3.3.4 CHECKING OIL LEVEL

See the "BEFORE STARTING THE GENERATOR" section for
information on checking the oil level. The oil level should be
checked before each use, or at least every eight hours of operation.
Keep the oil level maintained.

3.3.5 CHANGING THE OIL AND OIL FILTER

Change the oil and filter after the first 30 hours of operation. Change
the oil every 100 hours or every season thereafter. If running this
unit under dirty or dusty conditions, or in extremely hot weather,
change the oil more often.
Hot oil may cause burns. Allow engine to cool before
draining oil. Avoid prolonged or repeated skin exposure
with used oil. Thoroughly wash exposed areas with
soap.
Use the following instructions to change the oil:
Clean area around oil drain cap.
Remove oil drain cap from the drain hose and oil fill plug to drain
oil completely into a suitable container.
When oil has completely drained, install oil drain cap and tighten
securely.
Place a suitable container beneath the oil filter and turn
filter counterclockwise to remove. Discard according to local
regulations.
Coat gasket of new filter with clean engine oil. Turn filter
clockwise until gasket contacts lightly with filter adapter. Then
tighten an additional 3/4 turn.
Fill oil sump with recommended oil and replace the oil fill plug. (See
"Before Starting the Generator" for oil recommendations).
Wipe up any spilled oil.
Dispose of used oil at a proper collection center.
Section 3 — Maintenance
Portable Generator System

3.3.6 REPLACING THE SPARK PLUG

Use Champion RC14YC spark plug or equivalent. Replace the
plug once each year. This will help the engine start easier and
run better.
1. Stop the engine and pull the spark plug wire off of the spark
plug.
2. To gain access, remove the four (4) socket head screws and
take off the side panel.
3. Clean the area around the spark plug and remove it from the
cylinder head.
4. Set the spark plug's gap to .76 mm (0.030 in.). Install the
correctly gapped spark plug into the cylinder head (Figure
12).
5. Push the boot firmly on the spark plug and install side panel.
Figure 12 – Spark Plug Gap

3.4 SERVICE AIR CLEANER

The engine will not run properly and may be damaged if using a
dirty air cleaner. Clean or replace the air cleaner paper filter every
200 hours or once a year (Figure 15). Clean or replace more often
if operating under dusty conditions. To clean or replace paper air
filter:
Remove air cleaner cover and remove paper filter (Figure 13).
Clean paper filter by tapping it gently on a solid surface. If the
filter is too dirty, replace it with a new one. Dispose of the old
filter properly.
Clean air cleaner cover. Next insert new paper filter into the base
of the air cleaner. Re-install air cleaner cover.
To order a new air filter, please contact the nearest authorized
service center at 1-888-GENERAC.