Kübler CODIX 54U Instrucciones De Puesta En Servicio página 19

Contador indicador electrónico
Ocultar thumbs Ver también para CODIX 54U:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settinfs
4.1 Polarity of the inputs
4.2 Switching on the 30 Hz filter (INP A, INP B)
4.3 Multiplying factor (totaliser)
4.4 Dividing factor (totaliser)
npn: switching for 0 V
pnp: switching for +U B
30 Hz filter off (f max)
Count and start/stop
inputs not damped
30 Hz filter on
Count and start/stop
inputs damped
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
4.5 Decimal point (totaliser)
4.6 RESET mode (totaliser)
4.7 Input mode (time meter)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
Start/Stop via Inp B.
Counting while Inp B
(Gate) not active or open
Start/Stop via Inp B.
Counting while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the counter
status.
19

Publicidad

Tabla de contenido
loading

Tabla de contenido