4.10 Display mode (frequency meter)
4.11 Max. time to wait until „0" is displayed
(frequency meter)
This parameter indicates, how long it takes, when
measuring is active, until „0" is displayed.

4.12 End of programming

16
Value conversion and
display in 1/s
Value conversion and
display in 1/min
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
Electronic display counter with
2 totalising ranges
C C o o d d i i x x 5 5 4 4 U U :
basic operating mode
1. Description
• 6-digit dislay counter with Reset function
• Red LED display, character height 14 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
2. Inputs
INP A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can be
adjusted individually for Counter 1 and Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of totaliser 1 and the display of totalis-
er 2. Press the key briefly to display for 2 sec-
onds the current function ("total1" or "total2"). If,
during this period of time, the right key is pressed
a second time, the device switches to the current
function and displays a confirmation ("total1" or
"total2") for 2 seconds. Then, the value of the
selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings